Dimensions & weights, Trim materials flowing differential pressure limit – Warren Controls 1800 Series Heavy Globe Control Valves User Manual
Page 6
6
2600 Emrick Blvd • Bethlehem, PA 18020 • USA •800-922-0085 • www.warrencontrols.com
DIMensIons & weIGHts
2-WAY
3-WAY
valves shown with Dl84 actuator as typical.
For additional actuator information see Series 1800 Product Specification and the
Installation Operation and Maintenance Instructions for the actuator in use.
Pressure ratings are PSIG
For applications below 32º consult factory
Body Pressure-Temperature Ratings:
Temperature
(F)
125 FLG
Iron
250 FLG
Iron
150 FLG
Steel
300 FLG
Steel
150 FLG
St Steel
300 FLG
St Steel
+32° To 100°
175
400
285
740
275
720
150°
175
400
272
710
255
670
175°
170
385
266
695
245
645
200°
165
370
260
680
235
620
225°
155
355
252
673
230
605
250°
150
340
245
667
225
590
275°
145
325
237
661
220
575
300°
140
310
230
655
215
560
325°
130
295
222
650
210
548
350°
125
280
215
645
205
537
375°
-
265
207
640
200
526
400°
-
250
200
635
195
515
450°
-
-
185
620
182
497
500°
-
-
170
605
170
480
550°
-
-
155
587
155
465
600°
-
-
140
570
140
450
650°
-
-
125
550
125
440
700°
-
-
110
530
110
435
750°
-
-
95
505
95
425
800°
-
-
80
410
80
420
Trim Materials
Flowing
Differential
Pressure Limit
316 Stainless Steel
100 PSID
Alloy 6
300 PSID