beautypg.com

Technical data, 3 atex (acc. 94/9/ec) temperature limits – KROHNE OPTIMASS 2400 User Manual

Page 35

background image

TECHNICAL DATA

6

35

OPTIMASS 2400

www.krohne.com

07/2014 - 4003533101- MA OPTIMASS 2400 R01 en

6.3 ATEX (acc. 94/9/EC) temperature limits

Ambient temp.

T

amb

°C

Max. medium

temp. T

m

°C

Temp. class

Max. surface

temp. °C

OPTIMASS 2400C with or without

heating jacket / insulation

40

40

T6

T70

55

T5

T85

90

T4

T120

130

T3-T1

T160

50

55

T5

T85

90

T4

T120

130

T3-T1

T160

65

65

T5

T95

130

T3-T1

T160

OPTIMASS 2400C Aluminium converter

housing - with or without heating jacket

/ insulation

40

40

T6

T70

55

T5

T85

90

T41

T120

130

T3 - T1

T160

50

55

T5

T85

90

T4

T120

130

T3 - T1

T160

65

1

65

T4-T1

T95

OPTIMASS 2400C Stainless Steel

converter housing - with or without

heating jacket / insulation

40

40

T6

T70

55

T5

T85

90

T4

T120

130

T3-T1

T160

50

55

T5

T85

90

T4-T1

T120

60

60

T5-T1

T90

1 depending on I/O option. Please call for more information.