TECHNICAL DATA

32

OPTIMASS 2400

www.krohne.com

07/2014 - 4003533101- MA OPTIMASS 2400 R01 en

On site calibration

±

0.5 kg/m

3

/ ±0.033 lbs/ft

3

Temperature

Temperature

Temperature

Temperature

Accuracy

±

1°C / ±1.8°F

Operating conditions

Maximum flow rates

Maximum flow rates

Maximum flow rates

Maximum flow rates

S100

420000 kg/h / 14698 lbs/min

S150

900000 kg/h / 33804 lbs/min

S250

2300000 kg/h / 84510 lbs/min

Custody transfer flow rates (mass)

Custody transfer flow rates (mass)

Custody transfer flow rates (mass)

Custody transfer flow rates (mass)

S100

11000...220000 kg/h / 404...8083 lbs/min

S150

25000...500000 kg/h / 919...18371 lbs/min

S250

60000...1200000 kg/h / 2205...44092 lbs/min

Custody transfer flow rates (volume)

Custody transfer flow rates (volume)

Custody transfer flow rates (volume)

Custody transfer flow rates (volume)

S100

11...220 m

3

/h / 1660...33210 bbl/day

S150

25...500 m

3

/h / 3774...75478 bbl/day

S250

60...1200 m

3

/h / 9057...181147 bbl/day

Assumes operating density 1000 kg/m

3

/ 62.4 lb/ft

3

Ambient temperature

Ambient temperature

Ambient temperature

Ambient temperature

Compact version with Aluminium

converter

-40...+60°C / -40…+140°F

Extended temperature range: 65°C / 149°F for some I/O options. For more

information contact manufacturer.

Compact version with Stainless Steel

converter

-40...+55°C / -40…+130°F

Remote versions

-40...+65°C / -40…+149°F

Process temperature

Process temperature

Process temperature

Process temperature

Flanged connection

-45…+130°C / -49…+266°F

Hygienic connection (S100 only)

Nominal pressure at 20

Nominal pressure at 20

Nominal pressure at 20

Nominal pressure at 20°C / 68

C / 68

C / 68

C / 68°F

F

F

F

Measuring tube (Duplex UNS S31803)

Measuring tube (Duplex UNS S31803)

Measuring tube (Duplex UNS S31803)

Measuring tube (Duplex UNS S31803)

PED 97/23/EC

-1…150 barg / -14.5…2175 psig

FM

-1…140 barg / -14.5…2030 psig

CRN / ASME B31.3

-1…100 barg / -14.5…1450 psig

Measuring tube (Super Duplex UNS S32760)

Measuring tube (Super Duplex UNS S32760)

Measuring tube (Super Duplex UNS S32760)

Measuring tube (Super Duplex UNS S32760)

PED 97/23/EC

-1…180 barg / -14.5…2610 psig

FM

-1…140 barg / -14.5…2030 psig

CRN / ASME B31.3 (pending)

-1…130 barg / -14.5…1885 psig

Outer cylinder

Outer cylinder

Outer cylinder

Outer cylinder

Non PED / CRN approved

Typical burst pressure > 100 barg / 1450 psig

PED approved secondary containment

-1...40 barg / -14.5...580 psig

-1...150 barg / -14.5...2175 psig (Duplex option)

Fluid properties

Fluid properties

Fluid properties

Fluid properties

Permissible physical condition

Liquids, gases, slurries

Permissible gas content (volume)

Contact manufacturer for information.

MA_OPTIMASS_2400_en_140515_4003533101_R01.book Page 32 Thursday, July 31, 2014 5:08 PM