TECHNICAL DATA

6

33

OPTIMASS 2400

www.krohne.com

07/2014 - 4003533101- MA OPTIMASS 2400 R01 en

Permissible solid content (volume)

Contact manufacturer for information.

Protection category (acc. to EN 60529)

IP 67, NEMA 4X

Installation conditions

Inlet runs

None required

Outlet runs

None required

Materials

Measuring tube

Stainless Steel UNS S31803 (1.4462)

Optional UNS S32760 (1.4501)

Spigot

Stainless Steel UNS J92205 (1.4470)

Optional UNS J93404 (1.4469)

Flanges

Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified

Optional Stainless Steel UNS S31803 (1.4462) (NACE approved)

Optional UNS S32760 (1.4501) (NACE approved)

Outer cylinder

Stainless Steel AISI 304 / 304L (1.4301 / 1.4307) dual certified

Optional Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified

Optional Stainless Steel UNS S31803 (1.4462)

1

Heating jacket version

Heating jacket version

Heating jacket version

Heating jacket version

Heating jacket

Stainless Steel 316L (1.4404)

Note: the outer cylinder is in contact with the heating medium

Remote versions

Remote versions

Remote versions

Remote versions

Junction box

Die cast Aluminium (polyurethane coating)

Process connections

Flange

Flange

Flange

Flange

DIN

DN100…300 / PN16…160

ASME

4...12" / ASME 150…1500

JIS

100A / 10...20K

Hygienic

Hygienic

Hygienic

Hygienic

Tri-clover

4"

Tri-clamp DIN 32676

DN100

Tri-clamp ISO 2852

4"

DIN 11864-2 Form A

DN100

Male thread DIN 11851

DN100

Male thread SMS

4"

Male thread IDF / ISS

4"

Male thread RJT

4"

Electrical connections

Electrical connections

For full details, including: power supply, power consumption etc., see

technical data for the relevant converter.

I/O

For full details of I/O options, including data streams and protocols, see

technical data for the relevant converter.