TECHNICAL DATA
26
DK32
www.krohne.com
04/2011 - 4000898801 MA DK32 Air purge set R02 en
7.4 Flow table DK32
Reference condition for gas measurements:
Reference condition for gas measurements:
Reference condition for gas measurements:
Reference condition for gas measurements:
The flow measurement of gases are refered to
Nl/h or Nm
3
/h: Volume flow in Normal state 0°C, 1.013 bar abs. (DIN 1343)
SCFM or SCFH: Volume flow in Standard state 15°C, 1.013 bar abs. (ISO 13443)
Measuring span:
10 : 1
Declaration of flow:
Values = 100%
Air: 20°C [68°F], 1,2 bar abs. [17.4 psia]
Air flow rate
Pressure drop
Cones
[l/h]
[SCFH]
[mbar]
[psig]
K 005
16
1
0.6
1
14
0.21
K 005
50
1.9
31
0.46
K 010
70
1
2.6
1
66
0.97
K 010
100
3.7
66
0.97
K 015
150
5.6
19
0.28
K 040
400
15
27
0.40
K 080
800
30
55
0.81
K 125
1250
45
42
0.62
K 200
2000
75
85
1.25
K 300
2500
90
117
1.72
K 340
3400
130
166
2.44
1 with titanium float
INFORMATION!
The operating pressure should be at least twice the pressure loss for liquids, and at least 5
times the pressure loss for gases! The specified pressure drops are valid for water and air at
maximum flow rate. Other flow ranges on request. Conversion of other media or operating data
(pressure, temperature, density, viscosity) is performed using the calculation method in
accordance with VDI /VDE Directive 3513