7

TECHNICAL DATA

24

DK32

www.krohne.com

04/2011 - 4000898801 MA DK32 Air purge set R02 en

DK32 - Indicator with limit switches

Approvals

Cable fitting DK32/Kx/S

M16 x 1,5

Cable diameter DK32/Kx/L

7 ... 8mm

Clamp connection DK32/Kx/S

1.5mm

2

Limit switch

SC2-N0

I7S2002-N

SJ2-SN

1

SJ2-S1N

1

Type

2-wire NAMUR

2-wire NAMUR

2-wire NAMUR

Switch element function

Normally closed

Normally closed

Normally open

Nominal voltage U

0

8VDC

8VDC

8VDC

Pointer shaft not read

≥3mA

≥3mA

≤1mA

Pointer shaft read

≤1mA

≤1mA

≥3mA

DK32 with reed contact

Switching type

bistable

Switching reproducibility

<5% of full scale value

Breaking capacity

12VA

2

Max. supply voltage

30VDC

2

Max. current

0,5A

2

1 safety oriented
2 reduced values for Ex version

Standard

Indicator

Designation

ATEX

DK32 mechanical

II2GD IIC

II3GD IIC

DK32 electrical

II2G Ex ia IIC T6

IEC Ex

DK32 electrical

Ex ia IIC T6

FM

DK32

IS/I/1/ABCD;T6

NI/I/2/ABCD;T6

S/II, III/2/FG;T6

IS/I, II, III/1/A-G

NI/II/2/ABCD

Nepsi

DK32

Ex nL IIC T1-T6

Ex nA II T1-T6

MA_DK32_Purge_R02_en_898801_PRT.book Page 24 Wednesday, April 6, 2011 3:01 PM