TECHNICAL DATA

32

OPTIFLUX 2000

www.krohne.com

4/2014 - 4000839504 - HB OPTIFLUX 2000 R04 en

Grounding rings

Standard: stainless steel

Option: Hastelloy

®

C, titanium, tantalum

Grounding rings can be omitted with virtual reference option for the

IFC 300 signal converter.

Reference electrode

(optional)

Standard: Hastelloy

®

C

Option: stainless steel, titanium

Other materials on request

Process connections

Flange

Flange

Flange

Flange

EN 1092-1

DN25...3000 in PN 2.5...40

ASME

1…24" in 150 & 300 lb RF

JIS

DN25…1000 in 10...20 K

AWWA

DN700...2000 in 6...10 bar

Design of gasket surface

RF

Other sizes or pressure ratings on request.

Electrical connections

For full detail; see the relevant documentation of the signal converter

Signal cable

Signal cable

Signal cable

Signal cable (remote versions only)

Type A (DS)

In combination with the IFC 050, IFC 100 and IFC 300 signal converter

In combination with the IFC 050, IFC 100 and IFC 300 signal converter

In combination with the IFC 050, IFC 100 and IFC 300 signal converter

In combination with the IFC 050, IFC 100 and IFC 300 signal converter

Standard cable, double shielded.

Max. length: 600 m / 1950 ft

(depends on electrical conductivity and measuring sensor)

Type B (BTS)

Only in combination with the IFC 300 signal converter

Only in combination with the IFC 300 signal converter

Only in combination with the IFC 300 signal converter

Only in combination with the IFC 300 signal converter

Optional cable, triple shielded.

Max. length: 600 m / 1950 ft

(depends on electrical conductivity and measuring sensor)

I/O

For full details of I/O options, including data streams and protocols, see

technical datasheet of the relevant signal converter.

Approvals and certificates

CE

CE

CE

CE

This device fulfils the statutory requirements of the EC directives. The

manufacturer certifies successful testing of the product by applying the CE

mark.

Electromagnetic

compatibility

Directive: 2004/108/EC, NAMUR NE21/04

Harmonized standard: EN 61326-1 : 2006

Low voltage directive

Directive: 2006/95/EC

Harmonized standard: EN 61010 : 2010

Pressure equipment

directive

Directive: 97/23/EC

Category I, II, III or SEP

Fluid group 1

Production module H