Technical data – KROHNE OPTIFLUX 2000 EN User Manual
Page 29
TECHNICAL DATA
6
29
OPTIFLUX 2000
www.krohne.com
4/2014 - 4000839504 - HB OPTIFLUX 2000 R04 en
Measuring accuracy
Reference conditions
Medium: water
Temperature: +10...+30°C / +50...+86°F
Operating pressure: 1 bar / 14.5 psi
Inlet section ≥ 5 DN
Electrical conductivity: ≥ 300 μS/cm
Maximum measuring
error
IFC 050: 0.5% of the measured value above 0.5 m/s; below 0.5 m/s, deviation
±
2.5 mm/s
IFC 100: down to 0.3% of the measured value ±1 mm/s
IFC 300: down to 0.2% of the measured value ±1 mm/s
The maximum measuring error depends on the installation conditions.
For detailed information refer to
Measuring accuracy
on page 39.
Repeatability
±
0.1% of the measured value, minimum 1 mm/s
Calibration / Verification
Standard:
Standard:
Standard:
Standard:
2 point calibration by a direct volume comparison.
Optional:
Optional:
Optional:
Optional:
Verification to Measurement Instrument Directive (MID), Annex MI-001.
Standard: Verification at Ratio (Q3/Q1) = 80, Q3 ≥ 2 m/s
Optional: Verification at Ratio (Q3/Q1) > 80 on request
Only in combination with the IFC 300 signal converter.
MID Annex MI-001
(Directive 2004/22/EC)
EC-Type examination certificate to MID Annex MI-001
EC-Type examination certificate to MID Annex MI-001
EC-Type examination certificate to MID Annex MI-001
EC-Type examination certificate to MID Annex MI-001
Only in combination with the IFC 300 signal converter.
Diameter range: DN25...1600
Forward and reverse (bi-directional) flow
Liquid temperature range: +0.1°C / 50°C
For detailed information refer to
Legal metrology
on page 34.
OIML R49
Certificate of conformity to OIML R49
Certificate of conformity to OIML R49
Certificate of conformity to OIML R49
Certificate of conformity to OIML R49
Only in combination with the IFC 300 signal converter.
Diameter range
Class 1:DN65...1600
Class 2: DN25...50
Forward and reverse (bi-directional) flow
Liquid temperature range: +0.1°C / 50°C
For detailed information refer to
Legal metrology
on page 34.