6

TECHNICAL DATA

28

OPTIFLUX 2000

www.krohne.com

4/2014 - 4000839504 - HB OPTIFLUX 2000 R04 en

6.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Measuring principle

Faraday's law of induction

Application range

Electrically conductive fluids

Measured value

Measured value

Measured value

Measured value

Primary measured value

Flow velocity

Secondary measured

value

Volume flow

Design

Features

Fully welded maintenance-free sensor.

Large diameter range DN25...3000

Rugged liners approved for drinking water.

Large standard range but also available in customer specific diameter,

length and pressure rating.

Modular construction

The measurement system consists of a flow sensor and a signal converter. It

is available as compact and as separate version. Additional information can

be found in the documentation of the signal converter.

Compact version

With IFC 050 converter: OPTIFLUX 2050 C

With IFC 100 converter: OPTIFLUX 2100 C

With IFC 300 converter: OPTIFLUX 2300 C

Remote version

In wall (W) mount version with IFC 050 converter: OPTIFLUX 2050 W

In wall (W) mount version with IFC 100 converter: OPTIFLUX 2100 W

In field (F), wall (W) or rack (R) mount version with IFC 300 converter:

OPTIFLUX 2300 F, W or R

Nominal diameter

With IFC 050 converter: DN25...1200 / 1…48"

With IFC 100 converter: DN25...1200 / 1…48"

With IFC 300 converter: DN25...3000 / 1…120"