KROHNE IFC 020 Short EN User Manual
Page 14
Condensed instructions IFC 020
3/1
3 Start-up
•
Before powering the system, please check that it has been correctly installed according
to Sect. 1 and 2.
•
The flowmeter is delivered ready for operational use. All operating data have
been factory set in accordance with your specifications.
Please refer to Sect. 3.2 “factory settings”.
•
Power the unit, and the flowmeter will immediately start process flow measurement.
•
When powered, the display shows in succession: START UP and READY.
This is followed by display of the current flow rate and/or the current totalizer count
on either a continuous or alternating basis, depending on the setting under Fct. 1.04.
•
Refer to Sect. 4 and 5 for operator control of the “display version”.
3.1 Power-on and measurement
3.2 Factory setting
All operating data are factory set according to your order specifications.
If you have not made any particular specifications at the time of ordering, the instruments will be
delivered with the standard parameters and functions listed in the Table below.
To facilitate easy and rapid initial start-up, current output and pulse output are set to process flow
measurement in “2 flow directions”, so that the current flowrate is displayed and the volumetric
flow counted independent of the flow direction. On instruments equipped with a display, measured
values may possibly be shown with a “ – ” sign.
This factory setting for the current and pulse outputs may possibly lead to measuring errors,
particularly in the case of volume flow counting:
for example, if pumps are switched off and a “backflow” occurs which is not within the range of the
low-flow cutoff (SMU), or if separate displays and counts are required for both flow directions.
To avoid faulty measurements, therefore, it may be necessary to change the factory setting of
some or all of the following functions:
– low-flow cutoff SMU, Fct. 1.03, Sect. 5.3
– current output I, Fct. 1.05, Sect. 5.6
– pulse output P, Fct. 1.06, Sect. 5.7
– display (option), Fct. 1.04, Sect. 5.4
Operation see Section 4 and 5.
Standard factory settings
Function
Setting
1.01 Full-scale range Q
100%
see nameplate
1.02 Time constant
3 s, for I, S
and display
1.03 Low-flow
ON: 1 %
cutoff SMU
OFF: 2 %
1.04 Display (option)
flow rate
m
3
/hr or US Gal/min
totalizer(s)
m
3
or US Gal
1.05 Current output I
function
2 directions
range
4 - 20 mA
error message
22 mA
1.06 Pulse output P
function
2 directions
pulse value
1 pulse/s
pulse width
50 ms
1.07 Status output S
flow directions
Function
Setting
1.08 Control input
off
3.01 Language for display only English
3.02 Flowmeter
diameter
see nameplate
flow direction (see arrow
+ direction
on primary head)
}
3.04 Entry code
no
3.05 User unit
Liter/hror USMGal/day
3.06 Application
steady
3.07 Measuring point
Altometer
3.08 Communication interface off