beautypg.com

Technical data – KROHNE PTD 600 EN User Manual

Page 18

background image

7

TECHNICAL DATA

18

PTD 600

www.krohne.com

03/2012 - 4001946801 - MA PTD 600 R01 en

Materials

Sensor housing

Stainless steel 1.4404 / 316L or Hastelloy

®

C

Process connection

Stainless steel 1.4404 / 316L or Hastelloy

®

C

Process connections

Standard

G1 connection with flush hygienic cone in combination with hygienic

process connection adapters like the Tri-Clamp, 11851, Varivent (see

the "Accessories" data sheet for details)

Optional

G½ with flush hygienic cone

DN40/DN50 clamp acc. to DIN 32676

38/51 mm clamp ISO 2852

1½" Tri-Clamp and GEA Tuchenhagen type N connection

Electrical connection

Power supply

8...30 VDC

Load resistance

R

Load

[Ω] = (U

Supply

[V] - 8 V) / 20 [mA]

Output signal

4...20 mA

Insulation resistance

>100 MΩ at 750 V

Cable feedthroughs

Compact housing: M12 plug made of stainless steel (1.4404 / 316L)

Field housing: M16 made of stainless steel (1.4404 / 316L)

Approvals and certificates

CE

The device fulfils the statutory requirements of the EC directives. The

manufacturer certifies that these requirements have been met by

applying the CE marking.

Electromagnetic compatibility (EMC)

2004/108/EC in accordance with EN 61000-6-2 and EN 61000-6-3

Pressure equipment directive

97/23/EC

Other standards and approvals

Other standards and approvals

Other standards and approvals

Other standards and approvals

Vibration according to IEC 60068-2-6

1.5 mm (10...55 Hz), 10 g (58 Hz...2 KHz), 10 cycles within 2.5 h per

axis

Shock test in accordance with IEC 60068-2-27

50 g/11 ms, 100 g/6 ms, 10 x pulse/axis and direction

Bump in accordance with IEC 60068-2-29

100 g/2 ms, 4000 x pulse/axis and direction

Statistical failures in accordance with

IEC 60068-2-64

0.1 g

2

/Hz (20 Hz...1 KHz), 30 min. per axis (>10 g RMS)

Hygiene

FDA approved materials

.book Page 18 Friday, March 23, 2012 10:14 AM