Technical data – KROHNE PTD 600 EN User Manual
Page 18
7
TECHNICAL DATA
18
PTD 600
www.krohne.com
03/2012 - 4001946801 - MA PTD 600 R01 en
Materials
Sensor housing
Stainless steel 1.4404 / 316L or Hastelloy
®
C
Process connection
Stainless steel 1.4404 / 316L or Hastelloy
®
C
Process connections
Standard
G1 connection with flush hygienic cone in combination with hygienic
process connection adapters like the Tri-Clamp, 11851, Varivent (see
the "Accessories" data sheet for details)
Optional
G½ with flush hygienic cone
DN40/DN50 clamp acc. to DIN 32676
38/51 mm clamp ISO 2852
1½" Tri-Clamp and GEA Tuchenhagen type N connection
Electrical connection
Power supply
8...30 VDC
Load resistance
R
Load
[Ω] = (U
Supply
[V] - 8 V) / 20 [mA]
Output signal
4...20 mA
Insulation resistance
>100 MΩ at 750 V
Cable feedthroughs
Compact housing: M12 plug made of stainless steel (1.4404 / 316L)
Field housing: M16 made of stainless steel (1.4404 / 316L)
Approvals and certificates
CE
The device fulfils the statutory requirements of the EC directives. The
manufacturer certifies that these requirements have been met by
applying the CE marking.
Electromagnetic compatibility (EMC)
2004/108/EC in accordance with EN 61000-6-2 and EN 61000-6-3
Pressure equipment directive
97/23/EC
Other standards and approvals
Other standards and approvals
Other standards and approvals
Other standards and approvals
Vibration according to IEC 60068-2-6
1.5 mm (10...55 Hz), 10 g (58 Hz...2 KHz), 10 cycles within 2.5 h per
axis
Shock test in accordance with IEC 60068-2-27
50 g/11 ms, 100 g/6 ms, 10 x pulse/axis and direction
Bump in accordance with IEC 60068-2-29
100 g/2 ms, 4000 x pulse/axis and direction
Statistical failures in accordance with
IEC 60068-2-64
0.1 g
2
/Hz (20 Hz...1 KHz), 30 min. per axis (>10 g RMS)
Hygiene
FDA approved materials
.book Page 18 Friday, March 23, 2012 10:14 AM