3

INSTALLATION

10

PTD 600

www.krohne.com

03/2012 - 4001946801 - MA PTD 600 R01 en

Versions with cooling neck

Versions with cooling neck

Versions with cooling neck

Versions with cooling neck

To ensure proper cooling function, versions with cooling neck (T

Medium

≤ 200°C / 392°F) must be

installed at a maximum 10° angle to the horizontal.

3.4 Hygiene

• The mounting position, connection piece and sealing point should be designed so that the

system is completely self-draining and there are no hollow spaces.

• The transmitters are designed for CIP and SIP:

T

max

= 150°C / 302°F < 60 minutes for hygienic process connections;

T

max

= 125°C / 257°F for devices with thread connection

• It is not possible to sterilise the entire transmitter without protective devices in place.

.book Page 10 Friday, March 23, 2012 10:14 AM