beautypg.com

Assembled equipment – KROHNE BM 26 BASIC-ADVANCED ATEX EN User Manual

Page 24

background image

4

ASSEMBLED EQUIPMENT

24

BM 26 BASIC/ADVANCED

www.krohne.com

12/2011 - 4000347102 - AD ATEX BM 26 Bas-Adv R02 en

Maximum ambient temperature: measuring chamber with limit switches

Maximum ambient temperature: measuring chamber with an analog transmitter (analog output or
HART

®

Communication) - Part 1

T2

+240

+464

T1

+300

+572

Temperature class

Maximum ambient temperature

Measuring chamber with non-

NAMUR limit switch

Measuring chamber with NAMUR

limit switch

[°C]

[°F]

[°C]

[°F]

T6

+68

+154

+58

+136

T5

+80

+176

+70

+158

T4

+80

+176

+80

+176

T3

+80

1

+176

1

+80

1

+176

1

T2

+80

1

+176

1

+78

1

+172

1

T1

+66

1

+150

1

+56

1

+133

1

1 the limit switch is certified for applications with temperature classes T6...T4. If the ambient temperature for this device is not more

than the maximum limit for temperature classes T6...T4, the limit switch can be attached to a measuring chamber for applications with
temperature classes T6...T1.

Temperature class

Maximum ambient temperature

4...20 mA

4...20 mA

(PR)

4...20 mA +

HART

4...20 mA +

HART (PR)

4...20 mA +

indicator

4...20 mA +

HART +

indicator

xF45xB1xx xF45xV1xx

xF45xC1xx xF45xW1xx xF45xE1xx

xF45xF1xx

T6

[°C]

+49

+59

+49

+59

1

1

[°F]

+120

+138

+120

+138

1

1

T5

[°C]

+64

-

+64

-

+59

+59

[°F]

+147

-

+147

-

+138

+138

T4

[°C]

+80

+80

+80

+80

+59

+59

[°F]

+176

+176

+176

+176

+138

+138

T3

[°C]

+80

2

+80

2

+80

2

+80

2

+58

2

+58

2

[°F]

+176

2

+176

2

+176

2

+176

2

+136

2

+136

2

T2

[°C]

+80

2

+80

2

+80

2

+80

2

+57

2

+57

2

[°F]

+176

2

+176

2

+176

2

+176

2

+135

2

+135

2

T1

[°C]

+74

2

+74

2

+74

2

+74

2

+74

2

+74

2

[°F]

+165

2

+165

2

+165

2

+165

2

+165

2

+165

2

1 Not allowed
2 The analog transmitter is certified for applications with temperature classes T6...T4. If the ambient temperature for this device is not

more than the maximum limit for temperature classes T6...T4, the analog transmitter can be attached to a measuring chamber for
applications with temperature classes T6...T1.

Temperature class

Maximum process temperature

[°C]

[°F]