background image

4

ASSEMBLED EQUIPMENT

22

BM 26 BASIC/ADVANCED

www.krohne.com

12/2011 - 4000347102 - AD ATEX BM 26 Bas-Adv R02 en

4.1.3 Categories

Equipment categories for assembled equipment:

• For data on equipment categories for the measuring chamber, refer to

Categories

on page 5.

• For data on equipment categories for the limit switch, refer to

Categories

on page 10.

• For data on equipment categories for the analog transmitter, refer to

Categories

on page 15.

4.2 Installation

4.2.1 Precautions

General notes

• For more data on the measuring chamber, refer to

Precautions

on page 6.

• For more data on the limit switch, refer to

Precautions

on page 12.

• For more data on the analog transmitter, refer to

Precautions

on page 17.

WARNING!
When you install the device, obey the conditions in the EC-Type Examination certificates for the
applicable equipment. These conditions include:

The special conditions for safe use.

The Essential Health and Safety Requirements.

WARNING!
Insulation of the limit switch

Insulation of the limit switch

Insulation of the limit switch

Insulation of the limit switch
The Ex data for this device is only applicable if you obey these instructions:

Do not cover the limit switch housing with insulation.

Make sure that there is approximately 15 mm / 0.6

¨

of empty space between the limit switch

and the insulation.

Figure 4-1: Limit switches and insulation for the measuring chamber

1 Limit switch housing
2 Insulation around the measuring chamber (cross-section)
3 Measuring chamber (cross-section)
Empty space between the limit switch and the insulation for the measuring chamber, a ≥15 mm /0.6¨.