Technical data – KROHNE H250 M9 ES EN User Manual
Page 34
7
TECHNICAL DATA
34
H250
www.krohne.com
09/2012 - 4002294201 MA H250 KINAX R01 en
H250/RR - Stainless Steel, H250/HC - Hastelloy
®
Measuring span 10 : 1; flow values 100%
Reference condition:
Water 68°F
Air 68°F - 14.7 psi
Remarks:
• Air measurement - TIV float: heating not possible.
• The indicated pressure losses are valid for water and air at maximum flow rate.
• Other flow ranges on request.
• Conversion of other media or operating data is performed using the calculation method in
accordance with VDI /VDE Directive 3513.
Water
Air
Max. pressure loss
Float
TIV
CIV
DIV
TIV
Alu
TIV
DIV
TIV
Alu
TIV
CIV
DIV
Nominal
meter size
Cone
[GPH]
[SCFM]
[psig]
DN15, ½"
K 15.1
4.76
6.60
-
0.26
0.40
-
0.18
0.31
0.38
-
K 15.2
7.93
10.6
-
0.43
0.62
-
0.18
0.31
0.38
-
K 15.3
14.5
16.6
-
0.62
0.93
-
0.18
0.31
0.38
-
K 15.4
21.1
26.4
-
1.05
1.36
-
0.18
0.31
0.38
-
K 15.5
31.7
42.3
-
1.55
2.23
-
0.18
0.31
0.38
-
K 15.6
52.8
66.0
-
2.60
3.41
-
0.18
0.31
0.38
-
K 15.7
92.5
106
185
4.15
6.20
11.2
1
0.18
0.31
0.41
0.56
K 15.8
132
166
264
6.20
8.68
17,4
2
0.19
0.32
0.47
0.74
K 15.8
-
-
423
3
-
-
31.0
3
-
-
-
1.25
DN25, 1"
K 25.1
127
166
264
5.89
8.68
-
0.16
0.35
0.47
1.06
K 25.2
217
264
423
9.30
14.3
-
0.16
0.35
0.49
1.09
K 25.3
317
423
660
13.6
21.7
-
0.16
0.37
0.50
1.10
K 25.4
449
660
1057
22.9
31.0
68,2
2
0.18
0.38
0.56
1.15
K 25.5
845
1057
1664
38.4
58.9
111
1
0.19
0.44
0.66
1.51
4
DN50 2"
K 55.1
713
1664
2219
36.0
49.6
143
2
0.12
0.19
1.09
0.88
K 55.2
951
2642
3698
47.7
68.2
217
2
0.12
0.19
1.13
1.01
K 55.3
1347
4227
6604
68.2
93.0
434
2
0.13
0.19
1.23
1.53
DN80 3"
K 85.1
3170
6604
9774
152
217
620
2
0.12
0.24
1.00
1.40
K 85.2
4227
10567
16907
174
248
1116
2
0.13
0.24
1.31
1.84
DN100 4" K105.1
5019
16643
26418
-
341
1736
2
-
1.76
3.23
1 P >7.4 psig
2 P >7,4 psig
3 with TR float
4 4.4 psig with damping (gas measurement)
MA_H250_Sonder_Kinax_R01_en_4002294201_PRT.book Page 34 Monday, September 17, 2012 11:13 AM