7

TECHNICAL DATA

28

H250

www.krohne.com

09/2012 - 4002294201 MA H250 KINAX R01 en

7.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Application range

Flow measurement of liquids, gases and vapors

Operating method / measuring principle

Variable area measuring principle

Measured value

Primary measured value

Float position

Secondary measured value

Operating and standard volumetric flow

Measuring accuracy

Directive

VDI / VDE 3513, sheet 2 (q

G

= 50%)

H250 /RR /HC /F

1.6%

H250/C (Ceramic, PTFE)

H250H, H250U, H250 (100 : 1)

2.5%

Operating conditions

Temperature

Temperature

Temperature

Temperature

Max. operating temperature TS

-196..+300°C / -321...+572°F

Pressure

Pressure

Pressure

Pressure

Max. operating pressure PS

Depending on the version up to 400 bar / 5802 psig

Max. test pressure PT

Pressure equipment directive 97/23/EC or AD 2000-HP30

Min. required operating pressure

2 times greater than pressure loss (see measuring ranges)

Float damping during gas measurement recommended:

Float damping during gas measurement recommended:

Float damping during gas measurement recommended:

Float damping during gas measurement recommended:

DN15...25 / ½"...1"

Operating pressure <0.3 bar / 4.4 psig

DN50...100 / 2"...4"

Operating pressure <0.2 bar / 2.9 psig

Installation conditions

Inlet run

≥ 5 x DN

Outlet run

≥ 3 x DN

MA_H250_Sonder_Kinax_R01_en_4002294201_PRT.book Page 28 Monday, September 17, 2012 11:13 AM