TECHNICAL DATA
28
H250
www.krohne.com
09/2012 - 4002294201 MA H250 KINAX R01 en
7.2 Technical data
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).
Measuring system
Application range
Flow measurement of liquids, gases and vapors
Operating method / measuring principle
Variable area measuring principle
Measured value
Primary measured value
Float position
Secondary measured value
Operating and standard volumetric flow
Measuring accuracy
Directive
VDI / VDE 3513, sheet 2 (q
G
= 50%)
H250 /RR /HC /F
1.6%
H250/C (Ceramic, PTFE)
H250H, H250U, H250 (100 : 1)
2.5%
Operating conditions
Temperature
Temperature
Temperature
Temperature
Max. operating temperature TS
-196..+300°C / -321...+572°F
Pressure
Pressure
Pressure
Pressure
Max. operating pressure PS
Depending on the version up to 400 bar / 5802 psig
Max. test pressure PT
Pressure equipment directive 97/23/EC or AD 2000-HP30
Min. required operating pressure
2 times greater than pressure loss (see measuring ranges)
Float damping during gas measurement recommended:
Float damping during gas measurement recommended:
Float damping during gas measurement recommended:
Float damping during gas measurement recommended:
DN15...25 / ½"...1"
Operating pressure <0.3 bar / 4.4 psig
DN50...100 / 2"...4"
Operating pressure <0.2 bar / 2.9 psig
Installation conditions
Inlet run
≥ 5 x DN
Outlet run
≥ 3 x DN