2.2 H250 M9 Kinax – special version device

1. H250/RR/M9
• Local indicator without auxiliary power
• 2-wire current output 4…20 mA - type KINAX 3W2

2.2.1 Float damping

Float damping is characterised by high standstill times and self-centering. The damping sleeve
is made of high performance ceramic or PEEK, depending on the medium and the application.
Float damping can also be retrofitted for the user (see Service).

Use of damping

• Generally when CIV and DIV floats are used for gas measurement.
• For TIV floats (H250/RR and H250/HC only) with an operating primary pressure:

Nominal size acc. to

Operating primary pressure

EN 1092-1

ASME B16.5

[bar]

[psig]

DN 50

½

"

≤0.3

≤4.4

DN25

1"

≤0.3

≤4.4

DN50

2"

≤0.2

≤2.9

DN80

3"

≤0.2

≤2.9

DN 100

4"

≤0.2

≤2.9