beautypg.com

Temperature limits, 1 compact versions – KROHNE OPTIFLUX 2000-4000-5000-6000-7300-IFC 300 Ex EN User Manual

Page 24

background image

2

TEMPERATURE LIMITS

24

OPTIFLUX

www.krohne.com

07/2010 - 7309482600 - AD EX IFC 300 R06 en

2.3 OPTIFLUX 6000

2.3.1 Compact versions

• The OPTIFLUX 6300 C is suitable for an ambient temperature range of -40...+60°C.
• The minimum process temperature is -40°C.
• For dust hazardous areas the maximum surface temperature is 150°C at an ambient

temperature T

a

≤ 60°C.

• The maximum process temperature T

p

depends on the required temperature class T6...T3

and the maximum ambient temperature T

a

.

DN2.5...15

DN25...80

Temperature class

Max. process temperature Tp [°C]

T

a

≤ 40°C

40 < T

a

≤ 50°C

50 < T

a

≤ 60°C

T6

70

70

60

T5

85

85

60

T4

120

120

60

T3

150

140

60

Temperature class

Max. process temperature Tp [°C]

T

a

≤ 40°C

40 < T

a

≤ 50°C

50 < T

a

≤ 60°C

T6

75

70

65

T5

95

95

85

T4

130

130

85

T3

150

150

85