Temperature limits, 1 compact versions – KROHNE OPTIFLUX 2000-4000-5000-6000-7300-IFC 300 Ex EN User Manual
Page 22
2
TEMPERATURE LIMITS
22
OPTIFLUX
www.krohne.com
07/2010 - 7309482600 - AD EX IFC 300 R06 en
2.2 OPTIFLUX 5000
The maximum process temperature T
p
is dependent on the required temperature class T6...T3
and the maximum ambient temperature T
a
.
2.2.1 Compact versions
Sandwich versions
Sandwich versions
Sandwich versions
Sandwich versions
• For dust hazardous areas, the maximum surface temperature is equal to the process
temperature with a minimum of 85 °C.
• The OPTIFLUX 5300 C "sandwich" is suitable for an ambient temperature range of
-20...60°C (DN2.5...15) or -40...+60°C (DN25...100).
• The minimum process temperature is -20°C (DN2.5...15) or -40°C (DN25...100).
Flange versions
Flange versions
Flange versions
Flange versions
• The OPTIFLUX 5300 C "flange" is suitable for an ambient temperature range of
-40...+60°C.
• The minimum process temperature is -40°C.
Temperature class
Max. process temperature Tp [°C]
T
a
≤ 40°C
40 < T
a
≤ 50°C
50 < T
a
≤ 60°C
T6
60
55
-
T5
75
75
70
T4
115
115
75
T3
150
135
75
Temperature
class
Max. surface
temperature for
dust [°C]
Max. process temperature Tp [°C]
T
a
≤ 40°C
40 < T
a
≤ 50°C
50 < T
a
≤ 60°C
T6
85
80
80
60
T5
100
95
95
60
T4
135
135
130
60
T3
150
150
145
60