beautypg.com

Temperature limits, 2 field versions – KROHNE OPTIFLUX 2000-4000-5000-6000-7300-IFC 300 Ex EN User Manual

Page 23

background image

TEMPERATURE LIMITS

2

23

OPTIFLUX

www.krohne.com

07/2010 - 7309482600 - AD EX IFC 300 R06 en

2.2.2 Field versions

Sandwich versions

• The OPTIFLUX 5000 F is suitable for an ambient temperature range of

-20...65°C (DN2.5...15) or -40...+65°C (DN25...100).

• The minimum process temperature is -20°C (DN2.5...15) or -40°C (DN25...100).

Flange versions

• The OPTIFLUX 5000 F is suitable for an ambient temperature range of -40...65°C (DN15...100).
• The minimum process temperature is -40°C.

Temperature
class (for gasses)

Maximum surface
temperature for
dust [°C]

Max. process temperature Tp [°C]

T

a

≤ 40°C

40 < T

a

≤ 50°C

50 < T

a

≤ 65°C

T6

85

65

65

60

T5

95

85

85

75

T4

130

125

125

115

T3

180

180

165

140

Use heat

resistance cable

for T

p

above:

1

165

130

100

1 Cables must withstand a continuous operating temperature of 85°C.

Temperature
class (for gasses)

Maximum surface
temperature for
dust [°C]

Max. process temperature Tp [°C]

T

a

≤ 40°C

40 < T

a

≤ 50°C

50 < T

a

≤ 65°C

T6

85

80

80

75

T5

95

95

95

95

T4

130

130

130

130

T3

180

180

180

145

Use heat

resistance cable

for T

p

above:

1

never

165

90