beautypg.com

List:set:trig, List:set:wait – KEPCO KIT 219-0533, BOP 1000W Firmware Upgrade User Manual

Page 8

background image

8

228-1644 REV 7

091611

KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102

http://www.kepcopower.com email: [email protected]

where

is start point to be copied
is end point to be copied
is a series of comma separated values representing the new programmed current (Amps) for
current list, or programmed voltage (Volts) for voltage list.

Description: Copies points from existing list using the same dwell times, but different output settings. Copies the con-

tents of the dwell entries in the list from the start point to the end point and adds them to the end of the list. The set-
ting value for each copied point is defined by the value in the array. This process is repeated until either a) an
invalid programmed current or voltage is found, b) all entries in the array have been copied or c) the list is full.

This command must be preceded by LIST:CURR or LIST:VOLT command and the starting and end point values
must be valid, otherwise a -221 “Settings conflict” error results. The entries on the dwell list must match the values
in the current or voltage list, otherwise a -236 “Lists Unbalanced” error results. (See Figures B-2A and B-2B.)

B.34.1 [SOURce:]LIST:SET:TRIGger COMMAND

LIST:SET:TRIG

Syntax:

Short Form: LIST:SET:TRIG value
Long Form: LIST:SET:TRIGger value
where:
= trigger pulse-width between 0.00025 and 0.033 second

Description: Establishes external output trigger pulse-width. Used to set the pulse-width of a trigger provided by the BOP to

trigger an external device. (See Figure B-2B.)

B.34.2 [SOURce:]LIST:SET:TRIGger? QUERY

LIST:SET:TRIG?

Syntax:

Short Form: LIST:SET:TRIG?

Long Form: LIST:SET:TRIGger?

Returns = trigger pulse-width between 0.00025 and 0.033 second

Description: Returns pulse-width of output used to trigger external device.

If

sample pulse duration

has not been set,

error 100- “command error” results.

B.34.3 [SOURce:]LIST:SET:WAIT COMMAND

LIST:SET:WAIT

Syntax:

Short Form: LIST:SET:WAIT value
Long Form: LIST:SET:WAIT value
where: = time-out for a wait command between .00025 and .033 seconds

Description: Establishes the time-out for a wait command. If this command is not sent, the time out period will be 0 indicating

an infinite wait time. (See Figures B-2A and B-2B.)

B.34.4 [SOURCE:]LIST:SET:WAIT? QUERY

LIST:SET:WAIT?

Syntax:

Short Form: LIST:SET:WAIT?

Long Form: LIST:SET:WAIT?

Returns = time-out for a wait command between 0.00025 and 0.033 second

Description: Returns the time-out for a wait command. Returns 0 if LIST:SET:WAIT not sent, indicating infinite wait time.