beautypg.com

5 remote on-off, Dip switch settings for vdc on/alarm power options, R. 3.5) – KEPCO HSF 600W Series (suffix M and MZ) Operator Manuals User Manual

Page 13: Ble 5, R. 3.5, 8b). loa, Able 5, Able 5 list

background image

HSF (M) 600W 022713

11

FIGURE 8. DIP SWITCH SETTINGS FOR VDC ON/ALARM POWER OPTIONS

3.5

REMOTE ON-OFF

When power is ON at the source, the output may be turned ON or OFF using the ±RC signals if
the remote ON-OFF feature is enabled. Note that when remote ON-OFF is enabled, the RESET
OUTPUT switch does not function. Remote ON-OFF is enabled by setting DIP switch positions 3
and 4 as shown in Figure 9B. The +RC and –RC signals (at the rack adapter I/O connector, pins
15 and 8, respectively) then turn the unit on or off. These pins accept a logic level (2.4V to 24V
“high” and 0.0 to 0.4V “low”), or a contact closure. When the ±RC pins are open, using either a
mechanical switch or a high level logic signal, the HSF 600W output is cut OFF. When the ±RC
pins are shorted, the output returns to within specifications. At low level logic, the maximum
source current is 1.6mA and at high level the sink current is 1.0mA. Positions 3 and 4 of both DIP
switches must be restored to the factory default setting (Figure 9A) if remote ON-OFF is not used.
The ±RC pins are isolated from DC output pins and a-c input terminals.

FIGURE 9. DIP SWITCH SETTINGS FOR USING RESET BUTTON OR REMOTE ON-OFF

TABLE 5. MZ MODELS: CONDITIONS FOR VDC ON/ALARM LED

OPERATION POWERED BY OUTPUT

CONDITION

MODEL: HSF 12-53M HSF 15-43M HSF 24-27M HSF 28-23M HSF 48-13M

Minimum HSF output voltage required for VDC ON
LED to function when SW 2 position 8 is ON and SW 1
position 7 is OFF (Volts d-c)

3.3

3.5

4.5

5

8

3043747

7

7 DC ON PWR BY REF

7

SW1

8

SW2

8

OFF

ON

OFF

ON

USE REFERENCE SUPPLY

(FACTORY DEFAULT)

TO POWER "DC ON"

A

TO POWER "DC ON"

USE HSF OUTPUT VOLTAGE

B

(REQUIRES MINIMUM OUTPUT VOLTAGE)

7
8

8

SW1

7

SW2

OFF

ON

ON

OFF

DC ON PWR BY OUTPUT V 8

8

7

7
8

8

7

TAB

3042877

3

3 +RC

+RC 3

3

SW1

-RC 4

4

SW2

4

4 -RC

OFF

ON

OFF

ON

(FACTORY DEFAULT)

USE FRONT PANEL

RESET BUTTON

A

B

(LOGICAL LEVEL OR

MECHANICAL SWITCH)

USE REMOTE ON-OFF

3

3

SW2

SW1

4

4

ON

OFF

OFF

ON

3 +RC
4 -RC

+RC 3

-RC 4

TAB