beautypg.com

Verview – GW Instek GDS-2000A series Quick start guide for DS2-FGN User Manual

Page 3

background image

O

VERVIEW

The DDS Function Generator module allows the GDS-
2000A to create basic sine, square and triangle
waveforms.
To function properly, the DS2-FGN option needs to
work with GDS-2000A firmware version V1.16 or above.
Please refer to the CD for more details about updating
the firmware.

Main Features

Functions

Triangle, Sine, Square waveforms

Frequency

0.1Hz~5MHz (Sine, Square)

0.1Hz~500kHz (Triangle)

Amplitude

60mVpp ~ 6Vpp (into 1MΩ)

30mVpp ~ 3Vpp (into 50Ω)

DC Offset

±2V (into 1MΩ)

±1V (into 50Ω)

Duty Range

5 (min)% ~ 95% (max)
(Square wave only)

Default Settings

Frequency:

1kHz

Offset:

0V

Duty Cycle

1

:

50%

Amplitude:

3Vpp

1

Square wave only