This terminal board includes connectors for the following:

Table 1 Terminal Board Connectors

Terminal

Connector

Purpose

J1

4-Pin Connector

Modbus Out (Wireless Transceiver Option)

J2

6-Pin Header

Wireless Transceiver Programming Header

J3

6-Beau Connector

Battery operation or display interface dependent on sensor configuration

J4

4-Pin Connector

Modbus In

J5

6-Pin Connector

Display interface with battery/wireless configurations

J6

4-Pin Connector

Sensor connections

J7

4-Pin Connector

Auxiliary power in and mA out

J8

6-Pin Connector

Wireless Transceiver

J9

5-Pin Header

Terminal Board Programming

The Model 100 Display Terminal Board does not provide test points for measuring the milliamp (mA) output.
The mA output is available at J7.

NOTE

Install JP1 jumper on pins 1 and 2 if a battery pack is used. Install JP1 on pins 2 and 3 if
battery is not used.

1.5 DM-100 Series Display (Optional)

The DM-100 Series Display is a 4-digit LED display that provides a direct display of the sensor readings. In
units that are ordered with the optional display, the display is mounted directly onto the J3 Beau connector of
the Display Terminal Board so the display can be easily seen through the J-box window. The display
automatically identifies the ITM, the sensor type, and range. This factory installed option must be ordered with
the sensor assembly.

Figure 9 Model 100 Series Display

1.6 Wireless Transceiver and Battery Pack (Optional)

The DM-100 has the option to operate on a wireless network with the addition of a wireless transceiver and
battery pack. These options allow the sensor to be remotely mounted without the need for cables. These
options are factory installed. Contact Detcon for more information on these options.