beautypg.com

Sensor specific data, Table 3 sensor specific data, Table 3) – Detcon DM-100 User Manual

Page 33: 2 sensor specific data

background image

Model DM-100

DM-100 Instruction Manual

Rev. 3.3

Page 29 of 40

Analog Output:

Linear 4-20mA DC current
750 ohms maximum loop load @ 24VDC
1.2 mA

All Fault Diagnostics (without display)

2mA

Sensor in calibration (without display)

3.25mA

All Fault Diagnostics (with display)

3.5mA

Sensor in calibration (with display)

4-20 mA

0-100% full-scale

22 mA

Over-range condition

Cable Requirements:

Power/Analog: 2-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG

Mechanical Specifications

Length:

5.165 inches (131 mm), 8.5 inches (215mm) with Splash Guard

Width:

2.2 inches (55 mm)

Weight:

2.5 lbs (1.2 Kg)

Mechanical Connection:

3

/

4

" Male NPT threaded connection with locking nut

Electrical Connection:

four 18 gauge wire leads - 5.5" long

8.2 Sensor Specific Data

Table 3 Sensor Specific Data

Gas

GasName

Part Number

1

Response

Time

(seconds)

SpanDrift

Temperatur

e Range °C

Humidity

Range%

Warranty

O

2

Oxygen

371-343400-025

T95<30

<5%signal loss/year

-20 to+50

15 to 90

2 years

C

2

H

3

O

Acetyldehyde

371-12EA00-100

T90<140

<5%signal loss/year

-20 to+50

15 to 90

2 years

C

2

H

2

Acetylene

371-12EG00-100

T90<140

<5%signal loss/year

-20 to+50

15 to 90

2 years

C

3

H

3

N

Acrylonitrile

371-12EM00-100

T90<140

<5%signal loss/year

-20 to+50

15 to 90

2 years

NH

3

Ammonia

371-171700-100

T90<90

<2%signal

loss/month

-20 to+50

15 to 90

2 years

AsH

3

Arsine

371-191900-001

T90<60

<5%signal

loss/month

-20 to+40

20 to 95

1.5 years

Br

2

Bromine

371-747500-005

T90<60

<2%signal

loss/month

-20 to+50

15 to 90

2 years

C

4

H

6

Butadiene

371-12EB00-100

T90<140

<5%signal loss/year

-20 to+50

15 to 90

2 years

CO

Carbon
Monoxide

371-444400-100

T90=30

<5%signal loss/year

-40 to+50

15 to 90

3 years

Cl

2

Chlorine

371-747400-010

T90<60

<2%signal

loss/month

-20 to+50

15 to 90

2 years

ClO

2

(>10ppm) Chlorine Dioxide 371-777700-001

T90<60

<2%signal

loss/month

-20 to+50

15 to 90

2 years

ClO

2

(<=10ppm)

Chlorine Dioxide 371-282800-050

T90<120

<1%signal

loss/month

-20 to+40

10 to 95

2 years

B

2

H

6

Diborane

371-192100-005

T90<60

<5%signal

loss/month

-20 to+40

20 to 95

1.5 years

C

2

H

5

OH

Ethanol

371-12EO00-100

T90<140

<5%signal loss/year

-20 to+50

15 to 90

2 years

C

2

H

5

SH

Ethyl Mercaptan 371-24EZ00-100

T90<45

<2%signal

loss/month

-40 to+50

15 to 90

2 years

1

The last three digits of the Part Number are the range of the sensor cell. I.E. "-100" is a 100ppm range.