Model DM-100

DM-100 Instruction Manual

Rev. 3.3

Page 28 of 40

8. Appendix

8.1 Specifications

System Specifications

Sensor Type:

Continuous diffusion/adsorption type
3-Electrode Electrochemical Sensor (2-Electrode for O

2

)

Plug-in Replaceable Type

Sensor Life:

2 years typical

Measuring Ranges:

0-1ppm up to 0-10,000ppm (Toxic Gases)
0-1% up to 0-25% volume (O

2

)

Accuracy/ Repeatability:

±2% of full-range (other Toxic Gases)
±1% of full-range (O

2

)

Response Time:

T90 < 30 seconds typical (Table 3)

Electrical Classification:

CSA and US (NRTL)
Class I, Division 1, Groups A, B, C, D

ATEX
Class I, Zone 1, Group IIC
Ex d [ib] ib IIC T6

Approvals:

C

CSA

US

, ATEX, CE Marking

Warranty:

Electronics – 2 years
Sensor – (Table 3)

Environmental Specifications

Operating Temperature:

-40°C to +50°C typical (Table 3)

Storage Temperature:

-35°C to +55°C typical

Operating Humidity:

10-95% RH Continuous Duty (Table 3)
0-100% RH Short-Term Duration Only

Operating Pressure:

Ambient ± 10%

Air Velocity:

0-5 meters/second

Electrical Specifications

Input Voltage:

10-28 VDC

Power Consumption:

Normal operation = 4 mA (0.1 watts @ 24VDC);
Maximum = 20 mA (0.5 watts @ 24VDC; 0.23 watts @ 11.5VDC)

RFI/EMI Protection:

Complies with EN61326