Model DM-200

DM-200 Instruction Manual

Rev. 2.0

Page 29 of 40

9. Specifications


Sensor Type:

Continuous diffusion/adsorption type
3-Electrode Electrochemical Sensor (2-Electrode for O

2

)

Plug-in Replaceable Type


Sensor Life:

2 years typical


Measuring Ranges:

0-1 ppm up to 0-10,000 ppm (Toxic Gasses)

0-1%

up

to

0-25%

volume

(O

2

)


Accuracy/ Repeatability:

±2% of full-range (Toxic Gasses)

±1%

of

full-range

(O

2

)


Response Time:

T90 < 30 seconds typical (See Sensor Table)

Environmental Specifications

Operating Temperature:

-40°C to +50°C typical (See Table 3)

Storage Temperature:

-40°C to +50°C typical (See Table 3)

Operating Humidity:

10-95% RH Continuous Duty (See Table 3)

0-100%

RH

Short-Term

Duration

Only


Operating Pressure:

Ambient ±10%


Electrical Specifications

Input

Voltage:

11.5-30

VDC


Power Consumption

Normal operation = 4 mA (0.1 watts @ 24VDC);
Maximum = 20 mA (0.5 watts @ 24VDC)


RFI/EMI Protection:

Complies with EN61326


Analog Output:

Linear 4-20mA DC current

1000

ohms

maximum

loop

load

@

24VDC

3.5 mA All Fault Diagnostics

3.5 mA In-Calibration

4-20 mA 0-100% full-scale

Mechanical Specifications

Length:

12.5 inches (317.5 mm), Includes Splashguard


Width:

6.0

inches

(152.5

mm)


Weight:

5.6

lbs

(2.5

Kg)


Mechanical Connection:

¾” Male NPT threaded connection