3.2 A
PPLICATION
Model IR-640/IR-642 MicroSafe™ sensors are designed to detect and monitor CO2 gas in ambient air. Minimum sen-
sitivity and scale resolution is 0.01%. Operating temperature range is -40° F. to +175° F. While the sensor is capable of
operating outside these temperatures, performance specifications are verified within the limit.
3.2.1 Sensor Placement/Mounting
Sensor location should be reviewed by facility engineering and safety personnel.
3.3 S
PECIFICATIONS
Method of Detection
NDIR Optical
Electrical Classification
Class I; Groups B, C, D; Div. 1.
Response Time
Detcon Model IR-640/IR-642 Carbon Dioxide Sensor PG.6