Technical specifications, Mechanical, Performance/electrical – AW Gear Meters PROSCAN User Manual
Page 7: Preliminaries, Standard shipments, Unpack and check contents, Proscan in-line process sensor

ProScan In-Line Process Sensor
User Manual
6
Sanitary clamp connections
NEMA 6 /IP67 enclosure
Easy to install, set up and maintain
Technical Specifications
Mechanical
Materials: 316-series stainless steel housing and fittings; sapphire and FDA-approved silicone
product contact surface
Dimensions: 3.0" diameter x 3.6" length (approx.)
Weight: 4 lbs. (approx.)
Ratings: NEMA 4X (water-tight, corrosion proof); authorized to carry 3-A symbol
(Standard 46-03)
Optical Lens: uncoated, optical sapphire (aluminum oxide) min. thickness = 2.3mm
Lens Seal: 60 durometer, FDA-approved silicone rubber (meets ZZR-765-E, Class 2 A&B)
Lens Surface Finish: 0.1 microns/inch
£
Performance/Electrical
Accuracy: +/-0.2% of span at 4.00 mA (water)
Repeatability: +/-1.0% of span in any target fluid
Process Temp Range: 32° to 250°F (continuous)
Ambient Temp Range: 40° to 120°F
Process Temp Shock: withstands instantaneous changes of up to 125°F (e.g. From 40° to
165°F during CIP, or from 125° to 250°F during SIP)
Temperature Effect: 0.9% of span/10 deg F change (process and/or ambient) maximum
Process Temperature Limits: vacuum to 200 psig at rated temperature
Output: 4-20 mA, 3 or 4 wire
Power: 15-28 VDC, at 35 mA
Connection: 5 pin, water-tight, with quick-disconnect cabling
Preliminaries
Standard Shipments
Unless specified otherwise, ProScan sensors are shipped with a standard calibration covering a span of 4
to 20 mA and representing clean water at 4 mA and a maximum white standard at 20 mA. A calibration
document is included in the shipment to inform you of the calibration date and details.
Unpack and Check Contents
Upon receipt of the shipment, carefully remove all items from the shipping package and compare the
contents to the shipping documents.