beautypg.com

Ventamatic IF12P User Manual

Utility exhaust fan, Installation instructions, Installation

background image

UTILITY EXHAUST FAN

Models:

IF08P

IF12P

INSTALLATION INSTRUCTIONS

• Screwdriver
• Electric drill
• 1/8" drill bit
• Wire cutters
• Wire stripper
• UL approved wire nuts/connectors

TOOLS REQUIRED FOR INSTALLATION

Congratulations on your purchase of the MaxxAir™ Utility

Exhaut Fan. With proper care we are sure that you will enjoy

many years of use.
SAFETY INSTRUCTIONS:
1. Please read these instructions carefully before beginning

installation.

2. This fan is rated for 120V/60hz installations.
3. The plug on this fan is equipped with a ground. Do not

circumvent it.

4. Do not attempt to disassemble this fan.
5. This fan is designed for indoor use only.
6. This fan should not be installed near water.
7. This fan should not be submerged in water.
8. This fan is intended for general ventilating use only. Do not

use it to exhaust hazardous or explosive materials or vapors.

CAUTION: This fan has an unguarded impeller. DO NOT USE IN

LOCATIONS READILY ACCESSIBLE TO HUMANS OR ANIMALS.

Step 1: Determine the location to install the fan.

a) Must be a minimum of 1 ft from any adjacent wall or

ceiling.

b) Must be a minimum of 2.1m USA and 2.5m Canada

from the floor to the lowest moving part of the fan.

c) CAUTION: If installing into an existing wall, insure that

there are no hidden utilities or electrical wiring in this

location.

Step 2: Cut the opening into which the fan is to be

installed. Using the chart below, determine the appro-

priate cutout size for your model number fan. Measure

and cut out the opening for the fan.

Maintenance of Your Fan

Before conducting any maintenance on your fan

ensure that all electrical power to the fan is turned off.

Disassemble the fan for cleaning and/or maintenance.

1

. Wash the plastic parts with water lower than140°F

(60°C)

(Do not use gasoline, benzene or other

chemical agents.)

2

. Dry any remaining the water with clean rags or let

the fan dry naturally.

3

. Clean the motor and other electric components

with clean rags.

4

. Reassemble the fan.

INSTALLATION

Step 3: Remove the grill from the base unit.
Step 4: Position and secure the fan.
Standing on the

inside of the structure you are ventilating, insert the fan

into the cutout and secure to the wall using the screws

and plastic anchors that are provided.
Step 5: Reattach the grill to the fan and plug the unit

in. Pull the chain to cycle the fan on and off.

BACK OF FAN

IF08P 9 1/2” x 9 1/2“

IF12P 13 3/8” x 13 3/8”

Model Cutout

No.

Dimension

(portion of fan shaded in

grey will be inserted in

cutout opening)

A leader in the ventilation industry for over 60 years, Ventamatic, Ltd. offers a complete line of air movement

products for commercial, industrial, agricultural, and residential use sold under these fine names:

PLASTIC UTILITY FAN INSTALLATION INSTRUCTIONS (10/09)

©2009 VENTAMATIC, LTD

This manual is related to the following products: