Star Water Systems S1203 User Manual
Page 10
18
19
1. PowerFlush Optima is designed to accept additional
bathroom fixtures utilizing the two side inlets.
TYPICAL INSTALLATION
NOTE: All installations must comply with all applicable Electrical and
Plumbing Codes, including, but not limited, to National Electrical Code;
Local; Regional and/or State Plumbing Codes, etc.
8 Ft. Ceiling
7 Ft. Ceiling
Sub Floor
3/4” Thick
Minimum
2 x 8 Floor
Joists
8”
Min
ADDING OTHER BATHROOM FIXTURES
2. Additional fixtures can be attached either to the 2
in. MPT (outside diameter) or the 1½ in. slip (inside
diameter). These side inlets are sealed by the factory
to prevent leaks when inlets are not used. Before use,
these side inlets must be drilled out using a 1¾ in. hole
saw.
3. When utilizing side inlets, install a check valve on the
incoming line.
IL1759
Tub
Sink
Grinder
Pump
Unit Side
Inlets
Drill Point
1-1/2"
Slip Inside
2" MPT
Outside
IL1760
IL1761
Check
Valve
1
2
3