50
should choose a mount point from the list of mount points
managed by the embedded NTRIP caster.
Enable
Connect Now to allow the receiver to establish the
connection right after you have clicked on
Configure.
• In the
Message field, select the type of differential data the
base will deliver (ATOM, RTCM, CMR, CMR+ or DBEN).
Following your selection, you will see the detail of the
selected data on the right of this field, as defined in
Data
Output > Differential Messages.
• Resume the above settings for the second NTRIP server if
you need one.
• Click on the
Configure button to let the Web Server load all
your new parameters to the receiver. You have now
reached the end of the configuration phase.
RTK Corrections
Delivered on Port
A, B or F
• Unless already done, please follow all the steps described
in section General Parameters on page 35 before
proceeding with the steps below.
• If you intend to use port B or F for the connection to the
external radio, click on the
Connections - Serial Ports
submenu, enable the
Power ON option for serial ports B &F
(bottom of the page) and click on the
Configure button. If
port A will be used, skip this step.
• Come back to the
Base Setup page. In the Serial Port x pane
corresponding to the port you want the receiver to use (A,
B or F), set the following parameters:
–
Connection: Choose the name of the corrections
transmitter device connected to the port. As a general
rule, choose “None/Cable” for any external corrections
transmitter connected to that port. But if the device
used is a license-free radio, type ARF7474B EU or
ARF7474A NA, choose specifically this type of radio.
– Port settings (
Baud Rate, Mode, RTS/CTS): Set the serial
port to match the external device connected to it.
Setting these fields will update the corresponding
fields on the
Serial Ports sub-menu page.
RTK Corrections
A, B , F