Seed Hawk Air Drill Monitor 2008 User Manual
Page 13
![background image](/manuals/364525/13/background.png)
Seed Hawk Air Drill Monitor
SeedHawk Manual 01.doc
Not Released
Page 11
When the 400 feet has been driven, the operator can press the MODE key once again to stop
the pulse counting. This will bring up a standard SAVE screen. To save, select Y and then
press and hold OK until after the long beep. However, if the new count is less than 50, the
existing count is not replaced. To discard the changes, select N and then press the OK key.
3.3 Fan
DISPLAY 1 FUNCTION
RANGE
COMMENTS
PULSES
Pulses per revolution
on shaft sensor
0 to 4
Set to 0 to disable alarm
monitoring for this fan.
Default pulses/rev: 2
LO FAN
Low fan alarm point
1000 – HI
FAN
10 rpm increment/decrement.
Default alarm point: 1500 rpm
HI FAN
High fan alarm point
LO FAN -
9990
10 rpm increment/decrement.
Default alarm point: 5500 rpm
3.4 Shaft And Bin Level
DISPLAY 1 FUNCTION
RANGE
COMMENTS
PULSES
Pulses per revolution
on shaft sensor
0 to 99
Set to 0 to disable alarm
monitoring for this shaft.
Default pulses/rev: 27
LOSHFT
Low shaft alarm
0 to 999.5 0.5 rpm increment/decrement
Default alarm point: 0.5 rpm
WT/REV
Weight per Rev
0.000 to
5.000
Default weight per rev: 0 lb/rev
LEVEL
Alarm point for low bin
level
0 to 100
%
Set to 0 to disable alarm
monitoring for this bin.
Default level: 20%
When a shaft is disabled, the associated bin level will still function normally. To disable a bin
alarm, the LEVEL setting for that bin must be set to 0.