Maintenance, Maintenance schedule, Storage – Seed Hawk Ground Drive: Granular & Liquid 2011 User Manual
Page 46: 0 maintenance, 1 maintenance schedule, 2 storage

Seed Hawk
®
Manual
Granular and Liquid Tanks
Page 41
6.0 MAINTENANCE
6.1 MAINTENANCE SCHEDULE
Item
Procedure
Frequency
Notes
check
lube
clean
hours
Wheel Hubs
main frame
100
100 hr or annually
re-pack bearings or 2 pumps grease
Metering System
sprockets and chains
25
25 hr or every 2 days
use dry graphite lubricant
Metering Components
100
100 hr, or, before seeding, or,
between product changes
Fan System
intake
10
10 hr or daily
remove accumulated debris
Fan System
fan blades
10
10 hr or daily
must be intact and clean
Fill Auger or Conveyor
System
100
when changing between products, or,
when stored for long periods of time
Tanks and meters
100
When changing between products, or,
when stored for long periods of time
Fill Auger System
pillow block bearings
10/100
10 hr or daily, and,
100 hr or annually
Fill Auger System
universal joints
10/100
10 hr or daily, and,
100 hr or annually
Tank Return Line
open - drain in pail
100
at end of seeding season, or,
when stored for long periods of time
Tires
air pressure
10
10 hr or daily
inflate to proper pressure
NOTE: The bearings on each Stainless Steel meter are sealed.
DO NOT GREASE THESE BEARINGS.
6.2 Storage
Prior to storage remove all product from tanks and fill auger. As well, ensure that
the meters are emptied. If liquid tanks are equipped, purge all lines and add
antifreeze where necessary to avoid damage to liquid system caused by freezing.
NOTE: Failure to remove product prior to storage will greatly increase the
rate of corrosion in the tanks and meter.