0 hydraulic manifold blocks, 1 opener hydraulic blocks, 1 node light definitions – Seed Hawk TOOLBAR 2014 User Manual
Page 31: 2 node diagram, 1 toolbar only, 1 diagnosing node lights
![background image](/manuals/364501/31/background.png)
SEED HAWK
®
2014 TOOLBAR OPERATOR’S MANUAL
SEED HAWK
®
2014 TOOLBAR OPERATOR’S MANUAL
54
7.3.1 Node Light Definitions
Logic Power: Lights up solid when 12 V is present for Logic Power.
HC Power: Lights up soild when 12 V is present for High Current Power.
Micro 1Hz: Flashes once per second if processor is working correctly.
CAN Rx: Flashes intermittently when CAN communication is present going
TO the node.
CAN Tx: Flashes intermittently when CAN communication is present going
AWAY from the node.
Diagnostic 1 Light: Aircart Node: When solid; indicates that at least one of
the active products is not yet calibrated; e.g missing cal rate, meter cal or valve
cal.
Diagnostic 2 Light: Aircart Node: is not used in any connections.
7.3.1.1 Diagnosing Node Lights
CAN Rx/Tx: OFF - no CAN communication
CAN Rx/Tx: ON - partial CAN communication, possible break in CAN hi/lo
or poor connection.
Micro 1Hz: ON - Node locked up, spike or drop in voltage
Micro 1Hz: OFF - there is no logic power, if there is logic power then node
is bad or logic power is out of range (under 10 V), verify logic power into node
and check source of logic power.
7.3.2 Node Diagram
LOGIC
POWER
HC
POWER
MICRO
1Hz
CAN
Rx
CAN
Tx
DAIG 1
DIAG2
Logic Power
HC Power
Micro 1Hz
CAN Rx
CAN Tx
Diagnostics Light 1
Diagnostics Light 2
NOTE: The Diagnostic 2 light
should be ignored. Although
it blinks, it does not read any
sensors.
55
8.0 Hydraulic Manifold
Blocks
8.1 Opener Hydraulic Blocks
8.1.1 Toolbar Only
T
R-GP
P
RP
A1
B1
GP-2
RP
GP-1
P
T
Pressure
Tank
Inlet Pressure Gauge
PRV Pressure Gauge
Shank Pressure Gauge