5 configuring and handling alarms, 1 configuring alarm input and linked actions, Configuring and handling alarms – LT Security PTZ217X12 User Manual User Manual
Page 40: Configuring alarm input and linked actions, Figure 3-25 self-diagnostics

User Manual of 4-inch High Speed Dome
31
panning loss, tilting loss and communication loss.
Note:
Panning loss and tilting loss refer to the failures of panning and tilting, for diagnosing the
electric motor of the speed dome.
DIAGNOSTICS
HIGH TEMP 0
HIGHEST TEMP 35°C
LOW TEMP 0
LOWEST TEMP 14°C
VIDEO LOSS 0
LOW VOLATE 0
POWER UP 0
BACK EXIT
DIAGNOSTICS
PAN LOST 0
TILT LOST 0
CAMERA LOST 0
BACK EXIT
Figure 3-25 Self-diagnostics
3.5 Configuring and Handling Alarms
3.5.1 Configuring Alarm Input and Linked Actions
Purpose:
This section explains how to configure the speed dome to respond to alarm events with alarm
linked actions, such as calling presets, patrols, patterns, scanning, etc.
Steps:
1. Move the cursor to enter the alarm configuration submenu:
MAIN MENUS > DOME SETTINGS > ALARMS > ALARM SETTING
ALARM
ALARM RESUME ON
ALARM SEQUENCE 5
ALARM REST DELAY 5
ALARM SETTING
BACK EXIT
ALARM SETTING
ALARM NUM 1
PRIORITY HIGH
ALARM ACT NONE
AUX NONE
ALARM INPUT OPEN
BACK EXIT
Figure 3-26 Alarm Configuration Menu
2. Choose the alarm number.
Steps:
(1) Move the cursor to ALARM NUM and click the IRIS+ to enter edit mode.
(2) Click the up and down direction buttons to select the number of the alarm which is to be
configured.
(3) Click IRIS+ again to confirm and exit edit mode of this column.