Installation, Electrical installation, Warning – Lincoln Electric IM586 STT-10 Head & Controls User Manual

Page 16

background image

A-8

INSTALLATION

STT-10

A-8

ELECTRICAL INSTALLATION

Input Cable: STT-10 Control to Power
Source

Available Cable Assemblies:

K1758 Consists of an 8-conductor control cable with
a 14-pin plug, a 6-conductor control cable with a 10-
pin plug, and an electrode cable with Twist-Mate™
connector. It is rated at 300 amps, 60% duty cycle and
is available in lengths of 10 ft.(3 m), 25 ft.(7.6 m), and
50 ft.(15 m).

With input power disconnected from the power
source
, install the input cable per the following:

1) Connect the end of the control cable with the 14-

pin cable plug to the mating receptacle on the
power source. Connect the 10-pin cable plug to
the mating receptacle on the power source.

2) Connect the electrode lead to the power source

output terminal of the desired polarity.

3) Connect the 8-socket plug of the control cable to

the mating receptacle on the bottom of the STT-10
control box. Connect the 6-rocket plug of the con-
trol cable to the mating receptacle on the bottom of
the STT-10 control box.

4) Slip the current sensor cover off enough to expose

the input connector stud. Connect the electrode
cable from the power source to this stud with the
nut provided, then reclose the current sensor
cover.

Work Cable

Connect a work lead of sufficient size and length (per
the following table) between the proper output termi-
nal on the power source and the work. Be sure the
connection to the work makes tight metal-to-metal
electrical contact.

Observe all additional Safety Guidelines detailed throughout this manual.

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts such

as output terminals or internal wiring.

• When inching with gun trigger, electrode and

drive mechanism are “hot” to work and
ground and could remain energized several
seconds after the gun trigger is released.

• Turn OFF input power at welding power

source before installation or changing
drive roll and/or guide tubes.

• Welding power source must be connected

to system ground per the National
Electrical Code or any applicable local
codes.

Only qualified personnel should

perform this installation.

WARNING

Copper Work Cable Size, AWG

Up to 100 ft Length (30m)

Current

60% Duty

Cycle

400 Amps
500 Amps

#00 (67mm

2

)

#000 (85mm

2

)