PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Fault Code

Err 006

Err 100

Err 53 Voltage sense loss.

Err 81 Motor overload, long term.

Err 82 Motor overload, short term.

Err 95 Spool gun or pull gun motor

overload.

Err 263 No usable weld modes.

Description

1. The wire feeder has not received

a recognition command from the
power source.

1. The power source has issued a

shutdown command.

1. The wire drive motor has over-

heated.

1. The wire drive motor current draw

has exceeded limits, usually
because the motor is in a locked
rotor state.

1. The drive motor in the spool gun

or push-pull gun is drawing too
much current.

1. The power source does not have

any welding programs loaded.

Possible Adjustments

1. Verify the power source is operat-

ing properly. (Status light steady
green.)

2. Check control cable for loose or

broken leads.

3. See power source Instruction

Manual.

1. Verify the power source is operat-

ing properly (Status light steady
green.)

2. Check control cable for loose or

broken leads.

3. See power source Instruction

Manual.

1. Check that the electrode slides

easily through the gun and cable.

2. Remove tight bends from the gun

and cable.

3. Check that the spindle brake is

not too tight.

4. Verify a high quality electrode is

being used.

5. Wait for the error to reset and the

motor to cool. (approximately 1
minute).

1. Check that motor can turn freely

when idle arm is open.

2. Verify that the gears are free of

debris and dirt.

1. Check that the wire moves freely

through the gun when the gun is
straight.

2. Verify the correct size contact tip

is installed in the gun.

1. See the power source Instruction

Manual for load welding pro-
grams.

Linc-Net System Error Codes

ArcLink System Error Codes