Operation, B-10, Msp4 operation – Lincoln Electric IM892 POWER FEED 25M User Manual

Page 26: Std cv mig

background image

B-10

OPERATION

B-10

POWER FEED™ 25M

300

25.3

WFS AMPS

VOLTS TRIM

Less
WFS

Less
Volts

More
Volts

More
WFS

250

54

WFS AMPS

VOLTS TRIM

Less
WFS

Shorter
Arc

Longer
Arc

More
WFS

START OPTIONS

END OPTIONS

SET

SETUP

IR PORT

STD CV MIG

WAVEFORM CONTROL TECHNOLOGY

WELD MODE

ARC CONTROL

5

EFFECT / RANGE

Postflow Time
0 to 25.0 seconds

Crater Procedure
0 TO 10.0 SECONDS

Burnback:
0 to .25 Seconds

DESCRIPTION

Adjusts the time that shielding
gas flows after the welding out-
put turns off.
Crater Procedure controls the
WFS and Volts for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.

The burnback time is the

amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.

PROCESS

GMAW, STANDARD CV

GMAW, POWER MODE

FCAW, STANDARD CV

WELD MODE

5

40

6

ARC CONTROL

WELD MODE

END OPTIONS

START OPTIONS

DESCRIPTION

Pinch controls the arc characte-
-ristics when short-arc welding.

EFFECT / RANGE

(Soft)-10.0 to
(Crisp)+10.

PINCH

0

EFFECT / RANGE

Preflow Time
0 - 25.0 seconds

Run-In WFS:
Off, 30 to150 in/min.

Start Procedure
0 - 10 seconds

DESCRIPTION

Adjusts the time that shielding gas
flows after the trigger is pulled

and prior to feeding wire.

Run-In sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished.
The Start Procedure controls
the WFS and Volts for a speci-
fied time at the beginning of
the weld. During the start time,
the machine will ramp up or
down from the Start Procedure
to the preset Welding
Procedure.

Spot Timer

0 to 120.0 Seconds

Adjust the time welding will
continue even if the trigger
is still pulled. This option
has no effect in 4-Step
Trigger Mode.

Non-Synergic GMAW and FCAW Welding Display
Modes 5 and 6:

Mode 40:

MSP4 OPERATION