beautypg.com

Operation, B-21, B-21 gmaw-stt – Lincoln Electric IM892 POWER FEED 25M User Manual

Page 37: Msp4 operation

background image

B-21

OPERATION

B-21

GMAW-STT™

Waveform Control Technology™ maximizes the
ability to modify the arc for the perfect weld. When
STT™ welding, the parameters to control are:

• Wire Feed Speed - sets the deposition rate.
• Peak Current - controls the arc length.
• Background Current - regulates the bead contour.
• Tail-out - provides additional power in the arc.

There is no Voltage control when STT™ welding.

POWER FEED™ 25M

220

----

WFS AMPS

VOLTS TRIM

Less
Deposition

More
Deposition

EFFECT / RANGE

PEAK CURRENT

B A C K G R O U N D

CURRENT

TAIL OUT

( STT ll MODES

ONLY)

DESCRIPTION

Peak Current acts similar to an arc pinch
control. Peak Current sets the arc length
and promotes

-

good fusion. Higher peak

current levels will cause the arc to broaden

momentarily while increasing arc length. I f
set too high, globular transfer may occur.
Setting it too low may cause instability
and wire stubbing. Best practice is to

adjust for minimum spatter and puddle

agitation.

Background Current controls the overall

heat input in the weld.

Tail out provides additional power

without the molten droplet becoming

too large. Increase as necessary to add
heat input without increasing arc length.

Often this results in faster travel speeds.

Note that as tail out increases, the peak
current

to be reduced.

and/or background current may need

PREFLOW TIME

0 - 25.0 seconds

RUN-IN WFS:
Off, 30 to150 in/min.

Start Procedure

FUNCTION

Adjusts the time that shielding

gas flows after the trigger is

pulled and prior to feeding wire.

Run-in sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished.

The Start Procedure is not
commonly used with STT
procedures.

PARAMETER
RANGE

Postflow Time:
0 to 25.0 seconds

FUNCTION

Adjusts the time that shielding
gas flows after the welding out-
put turns off.

ELECTRODE AND GAS

STEEL CO

2

STAINLESS

Ar/CO

2

He/Ar/CO

2

STEEL CO

2

STAINLESS

Ar/CO

2

He/Ar/CO

2

WIRE SIZE

0.035 0.045 0.052

110 126 126

110 126 126

WELD MODES

START OPTIONS

END OPTIONS

ARC CONTROL

Steel
.035"

SET

SETUP

IR PORT

STT

WAVEFORM CONTROL TECHNOLOGY

WELD MODE

ARC CONTROL

109

START OPTIONS

END OPTIONS

STEEL CO

STEEL CO

STEEL AR/CO

STAINLESS He/Ar/CO

STAINLESS He/Ar/CO

STAINLESS Ar/CO

2

2

2

2

2

2

(with Hot Start)

(SYNERGIC STT)

SYNERGIC STT, OPEN ROOT

123 124 124

123 124 124

111 117 120

112 118 121

113 119 122

135 137 ---

127 129 ---
131 133 ---

Burnback: 0 to .25
Seconds

The burnback time is the
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.

Crater Procedure

Crater is not commonly used
in STT weld procedures.

Spot Timer

0 to 120.0 Seconds

Adjust the time welding will
continue even if the trigger
is still pulled. This option
has no effect in 4-Step
Trigger Mode.

MSP4 OPERATION