beautypg.com

Maintenance, Warning safety precautions – Lincoln Electric IM892 POWER FEED 25M User Manual

Page 72

background image

D-1

MAINTENANCE

D-1

POWER FEED™ 25M

ELECTRIC SHOCK can kill.

• Do not operate with covers

removed.

• Turn off power source before

installing or servicing.

• Do not touch electrically hot

parts.

• Turn the input power to the welding power

source off at the fuse box before working in the
terminal strip.

• Only qualified personnel should install, use or

service this equipment.

WARNING

SAFETY PRECAUTIONS

ROUTINE MAINTENANCE

• Check weld cables, control cables and gas hoses

for cuts.

• Clean and tighten all weld terminals.

PERIODIC MAINTENANCE

• Clean drive rolls and inner wire guide and replace if

worn.

• Blow out or vacuum the inside of the feeder.

CALIBRATION SPECIFICATION

All calibrations are factory set on the POWER FEED™
25M.

To verify the wire feed speed:

• Assemble a .045 (1.2mm) drive roll kit into the

POWER FEED™ 25M.

• Load a spool of .045 (1.2mm) electrode and thread

the electrode through the wire drive.

• Adjust the wire feed speed to 300 in/min

(7.62m/min).

• Press the COLD FEED switch and measure the

actual wire feed speed with a calibrated wire feed
speed tachometer.

• The measured wire feed speed should be within 2%

of the set value.

To verify the voltage display:

• Set the welding power source and POWER FEED™

25M to a CV procedure that gives steady "spray"
transfer in the arc.

• While a weld is being made, measure the voltage

from the feed plate to work with a calibrated volt
meter.

• The displayed voltage on the POWER FEED™ 25M

should be within 2% of the measured value.