A-3

INSTALLATION

POWER FEED™ 25M

A-3

Figure A.3

A

B

C

D

E

A

B

C

D

E

POWER SOURCE

WIRE FEEDER

Power Source

Pin

Function

A

ArcLink

B

ArcLink

C

"67" voltage sense

D

40 VDC

E

Common

Wire Feeder

Pin

Function

A

ArcLink

B

ArcLink

C

"67" voltage sense

D

40 VDC

E

Common

A

B

C

D

E

A

B

C

D

E

A

B

C

D

F

E

A

B

G

C

D

F

E

Function

5 pin trigger con-
nector for push-
only guns.

6 pin connector for
remote control or
foot/hand amptrol.

7 pin connector for
push-pull guns

Function

5 pin ArcLink con-
nector.

PIN

A
B
C
D
E

A
B
C
D
E
F

A
B
C
D
E
F

G

PIN

A
B
C
D
E

Wiring

Trigger

Not used
Common

Dual Procedure Selection

Common

77 Remote potentiometer, 5K

75 Remote potentiometer, common

76 Remote potentiometer, wiper

Switch, On/Off

Switch, common

Not used

Motor -

Motor +

77 Remote potentiometer, 5K

76 Remote potentiometer, wiper

Switch, On/Off

Switch, common

75 Remote potentiometer, common

Wiring

ArcLink
ArcLink

67 Electrode Voltage Sense

40VDC

Common

CABLE CONNECTIONS

There are three circular connectors on the front of the
POWER FEED™ 25M.
(See 5-pin, 6-pin and 7-pin- Figure A.1)

There is one circular connector on the rear of the POWER
FEED™ 25M. Maximum control cable length is 200 ft (61 m).

ARCLINK CONTROL CABLES

(See Figure A.3)
ArcLink Control Cables are available in two forms:

• K1543-xx series for most indoor or factory installa-

tions.

• K2683-xx series for outdoor use or when the equip-

ment is frequently moved.

ArcLink/LincNet control cables are special high quality
cables for digital communication. The cables are cop-
per 5 conductor cable in a SO-type rubber jacket.
There is one 20 gauge twisted pair for network com-
munications. This pair has an impedance of approxi-
mately 120 ohms and a propagation delay per foot of
less than 2.1 nanoseconds. There are two 12 gauge
conductors that are used to supply 40VDC to the net-
work. The fifth wire is 18 gauge and is used as an
electrode sense lead.

FIGURE A.1

FIGURE A.2

Use of non-standard cables may lead to system shut-
downs, poor arc starting and wire feeding problems.

The control cables connect the power source to the
wire feeder, and the wire feeder to other wire feeders.

Control cables may be connected end to end to
extend their length. Use a maximum of 200 ft.
(61.0m) of control cable between components.