Installation – Lincoln Electric IM571 RANGER 300 D and 300 DLX User Manual
Page 9

A-1
INSTALLATION
RANGER 300 D AND 300 DLX
A-1
TECHNICAL SPECIFICATIONS - Ranger 300 D (K1522-1), Ranger 300 DLX (K1522-2)
Make/Model
Description
Speed (RPM)
Displacement
Starting
Capacities
System
Kubota
3 cylinder
High Idle 3700
54.9 cu. in
12VDC battery
Fuel: 10 gal.
DH905
26.0 HP @
Low Idle 2150
(898 cc)
(Group 45, 495
38 L
Diesel Engine
3600 RPM
Full Load 3600
cold crank amps)
Bore x Stroke
1 KW Starter
Oil: 5.4 Qts.
30 A. Alternator
5.1 L
2.83” x 2.90”
w/ built in reg.
(72 mm x 73.6mm)
Coolant: 5.7 qts.
5.4 L
INPUT - DIESEL ENGINE
RATED OUTPUT - WELDER
HEIGHT WIDTH
DEPTH
WEIGHT
37.38 in.
24.75 in.
60.50 in.
1093 lbs. (300 D)
1133 lbs. (300 DLX)
949.4 mm
628.7 mm
1528.6 mm
480.8 kg. (300 D)
499.0 kg. (300 DLX)
OUTPUT - GENERATOR
Welding Output
Volts at Rated Amps
Duty Cycle
Max. OCV @ 3700 RPM
DC Constant Current 300 amps
25 volts
100%
AC Constant Current 300 amps
25 volts
100%
80 volts RMS
DC Constant Voltage (300 D) 200 amps
20 volts
100%
DC Constant Voltage (300 DLX) 300 amps
30 volts
60%*
DC Constant Voltage (300 DLX) 280 amps
30 volts
100%
Auxiliary Power
1
12,000 Watts, 60 Hz
120/240 Volts
100 % Duty Cycle
PHYSICAL DIMENSIONS
1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
* Duty cycle is based on a 10 minute period. The machine can be loaded to 300 amps for 6 minutes out of every 10 minute
period.