TECHNICAL SPECIFICATIONS - Ranger 300 D (K1522-1), Ranger 300 DLX (K1522-2)

Make/Model

Description

Speed (RPM)

Displacement

Starting

Capacities

System

Kubota

3 cylinder

High Idle 3700

54.9 cu. in

12VDC battery

Fuel: 10 gal.

DH905

26.0 HP @

Low Idle 2150

(898 cc)

(Group 45, 495

38 L

Diesel Engine

3600 RPM

Full Load 3600

cold crank amps)

Bore x Stroke

1 KW Starter

Oil: 5.4 Qts.

30 A. Alternator

5.1 L

2.83” x 2.90”

w/ built in reg.

(72 mm x 73.6mm)

Coolant: 5.7 qts.

5.4 L

INPUT - DIESEL ENGINE

RATED OUTPUT - WELDER

HEIGHT WIDTH

DEPTH

WEIGHT

37.38 in.

24.75 in.

60.50 in.

1093 lbs. (300 D)
1133 lbs. (300 DLX)

949.4 mm

628.7 mm

1528.6 mm

480.8 kg. (300 D)
499.0 kg. (300 DLX)

OUTPUT - GENERATOR

Welding Output

Volts at Rated Amps

Duty Cycle

Max. OCV @ 3700 RPM

DC Constant Current 300 amps

25 volts

100%

AC Constant Current 300 amps

25 volts

100%

80 volts RMS

DC Constant Voltage (300 D) 200 amps

20 volts

100%

DC Constant Voltage (300 DLX) 300 amps

30 volts

60%*

DC Constant Voltage (300 DLX) 280 amps

30 volts

100%

Auxiliary Power

1

12,000 Watts, 60 Hz

120/240 Volts

100 % Duty Cycle

PHYSICAL DIMENSIONS

1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to

rated capacity. When welding, available auxiliary power will be reduced.

* Duty cycle is based on a 10 minute period. The machine can be loaded to 300 amps for 6 minutes out of every 10 minute