CONNECTION DIAGRAMS

F-3

F-3

RANGER 300 D AND 300 DLX

CAUTION :

or service this equipment.

Keep away from moving parts.

Keep guards in place.

ELECTRODE

TO WORK

TO LN-742 INPUT
CABLE PLUG

14 PIN

K592 CONTROL CABLE

AMPHENOL

ELECTRODE CABLE

TO WORK

TO WIRE FEED UNIT

N.E. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

6-20-97

S23732-5

RANGER 300 DLX / LN-742 CONNECTION DIAGRAM

THE ENGINE WELDER OPERATING MANUAL.

WARNING

Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.

Only qualified personnel should install,use

Do not touch electrically live parts.

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

APPLICATIONS. SEE OPERATING MANUAL.

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

N.C. PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A WIRE WELDING-CV POSITION.

N.D. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION.

Disconnect NEGATIVE (-) BATTERY LEAD

Do not touch electrically live parts.

14 PIN

AMPHENOL

TO WORK

ELECTRODE

before servicing.

Do not operate with panels open.

TO WORK

CAUTION :

THE ENGINE WELDER OPERATING MANUAL.

PLACE LOCAL / REMOTE SWITCH IN "REMOTE" POSITION.

APPLICATIONS. SEE OPERATING MANUAL.

N.C. PLACE IDLER SWITCH IN "HIGH" POSITION.

Keep guards in place.

S23732-6

Keep away from moving parts.

WARNING

Only qualified personnel should install,use
or service this equipment.

TO LN-8 INPUT

K595 CONTROL CABLE

6-20-97

CABLE PLUG

RANGER 300 DLX / LN-8 CONNECTION DIAGRAM

ELECTRODE CABLE
TO WIRE FEED UNIT

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

N.B. USE POLARITY SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A WIRE WELDING-CV POSITION.