CONNECTION DIAGRAMS

F-4

F-4

RANGER 300 D AND 300 DLX

Keep away from moving parts.

31

NOT USED ON RANGER POWER SOURCES

42

TO WIRE FEED UNIT

ELECTRODE CABLE

ADAPTER PLUG

K867 UNIVERSAL

Only qualified personnel should install,use

82

41

81

Do not touch electrically live parts.

4

2

SPARE

6-20-97

S23732-7

CAUTION :

N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION

N.E. REFER TO POWER SOURCE INSTRUCTION MANUAL FOR MAXIMUM AUXILIARY CURRENT DRAW.

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

ELECTRODE

TO WORK

WARNING

THE ENGINE WELDER OPERATING MANUAL.

Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.

N.B. USE POLARITY SWITCH TO SET DESIRED POLARITY, POSITION THE RANGE SWITCH TO A WIRE WELDING-CV POSITION.

Keep guards in place.

or service this equipment.

CONNECT TOGETHER FOR

WELDING OUTPUT

115 VAC

N.E.

TO

2

4

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

RELAY TO CLOSE LEADS 2 & 4.

14 PIN

N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

TO WORK

AMPHENOL

RANGER 300 DLX TO K867 CONTROL CABLE ADAPTER CONNECTION DIAGRAM

K867

MIN.

WIRE

TO

FEEDER

N.D.

N.C.

REMOTE OUTPUT CONTROL

10K

75

WIRE FEEDER VOLTMETER CONNECTION

76

POWER SOURCE FRAME CONNECTION

77

CONNECTS TO (WORK TERMINAL) OF POWER SOURCE

42 VAC

21

GND

32

K488 SG

TO WORK

CONTROL MODULE

RECEPTACLE

14 PIN WIRE FEEDER

RANGER

115V RECEPTACLE

THE ENGINE WELDER OPERATING MANUAL.

K487-25
SPOOL GUN

BE SURE THAT CONTROL MODULE MODE SLIDE SWITCH IS IN THE "LINCOLN" (CONTACT CLOSURE) POSITION BEFORE ATTEMPTING TO OPERATE

CONTROL MODULE. INCORRECT SWITCH POSITION COULD RESULT IN DAMAGE TO THE CONTROL MODULE AND/OR POWER SOURCE.

before servicing.

ELECTRODE

RANGER 300 DLX / K691-10 / K488 / K487 SPOOL GUN CONNECTION DIAGRAM

Disconnect NEGATIVE (-) BATTERY LEAD

INPUT CABLE

K691-10

or service this equipment.

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

PLACE WELDING TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

Keep away from moving parts.

Do not operate with panels open.

WARNING

Keep guards in place.

Only qualified personnel should install,use

Do not touch electrically live parts.

N.C. IF OPTIONAL K857 REMOTE OUTPUT CONTROL IS CONNECTED TO 6 PIN RECEPTACLE,PLACE OUTPUT CONTROL SWITCH IN

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A WIRE WELDING-CV POSITION.

"OUTPUT CONTROL REMOTE" POSITION.
N.D. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.

6 PIN REMOTE

CAUTION :

S23732-8

TO CONTROL MODULE

ELECTRODE CABLE

RECEPTACLE

TO WORK

6-20-97