beautypg.com

Connection diagrams, Warning – Lincoln Electric IM571 RANGER 300 D and 300 DLX User Manual

Page 41

background image

F-1

CONNECTION DIAGRAMS

F-1

RANGER 300 D AND 300 DLX

(RANGER 300 DLX
ONLY)

6 PIN

AMPHENOL

TO WORK

14 PIN
AMPHENOL

LN-25

N.E. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

N.C. IF REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL REMOTE SWITCH IN "REMOTE" POSITION.

6-20-97

S23732-1

ELECTRODE CABLE

WIRE FEEDER

TO WORK

WORK CLIP LEAD

OPTIONAL K857

REMOTE CONTROL

N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE
AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

WARNING

or service this equipment.

Keep away from moving parts.
Only qualified personnel should install,use

RANGER 300 D & RANGER 300 DLX / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

WITH OPTIONAL K857 REMOTE CONTROL

N.D. ON RANGER 300 DLX, THE WELDING TERMINALS SWITCH MUST BE IN THE "ALWAYS ON" POSITION.

N.B. USE POLARITY SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO
A WIRE WELDING-CV POSITION.

Do not operate with panels open.

before servicing.

Disconnect NEGATIVE (-) BATTERY LEAD

Do not touch electrically live parts.

Keep guards in place.

ELECTRODE

TO WORK

S23732-2

RANGER 300 D & RANGER 300 DLX / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

(RANGER 300 DLX
ONLY)

N.C. IF REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL REMOTE SWITCH IN "REMOTE" POSITION.

N.B. USE POLARITY SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION RANGE SWITCH TO A
WIRE WELDING-CV POSITION.

N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE
AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.D. ON RANGER 300 DLX, THE WELDING TERMINALS SWITCH MUST BE IN THE "ALWAYS ON" POSITION.

6-20-97

ELECTRODE CABLE

WIRE FEEDER

OPTIONAL K444-1
REMOTE CONTROL

TO WORK

WORK CLIP LEAD

Keep guards in place.

or service this equipment.

Keep away from moving parts.
Only qualified personnel should install,use

WARNING

WITH OPTIONAL K444-1 REMOTE CONTROL

6 PIN

AMPHENOL

14 PIN
AMPHENOL

TO WORK

LN-25

Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.

Do not touch electrically live parts.

ELECTRODE

TO WORK

N.E. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.