beautypg.com

Troubleshooting, Caution – Lincoln Electric IM571 RANGER 300 D and 300 DLX User Manual

Page 38

background image

E-2

TROUBLESHOOTING

E-2

RANGER 300 D AND 300 DLX

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

Major Physical or Electrical Damage
is Evident.

Engine will not "crank".

Engine will "crank" but not start.

Engine shuts down shortly after
starting.

Engine shuts down while under load.

Battery does not stay charged.

1. Battery is low.
2. Loose battery cable connections.
3. Faulty engine starter motor.

1. Fuel shut off valve is in off posi-

tion.

2. Out of fuel.

3. Engine switch in "OFF" position.
4.

High coolant temperature
(Indicator light lit).

5. Faulty fuel solenoid or faulty PC

board.

1. Low oil level. Oil pressure indica-

tor light will flash while engine is
running.

2. Circuit breaker CB9 located in

engine compartment is open. Oil
pressure and charging indicator
lights will not be on when engine
switch is ON and engine is not
running if CB9 is tripped.

1.

High coolant temperature
(Indicator light lit).

1. Faulty battery.
2. Loose connections at battery or

alternator.

3. Loose fan belt.
4. Faulty engine alternator.

1. Contact your Local Lincoln Authorized

Field Service Facility.

1. Charge Battery.
2. Inspect, clean and tighten.
3. Contact authorized Kubota Service

Shop.

1. Move lever on fuel filter housing to

"ON" (vertical) position.

2. Fill tank and bleed fuel system. See

MAINTENANCE section

3. Set switch to "ON" position.
4. Check engine cooling system.

5. Contact your Local Lincoln Authorized

Field Service Facility for technical
troubleshooting assistance.

1. Change oil and oil filter and fill to prop-

er level. Start engine and look for
leaks.

2. Reset CB9. If it continues to trip, con-

tact your Local Lincoln Authorized
Field Service Facility for technical
troubleshooting assistance.

1. Reduce load if it is exceeding machine

rating. Add coolant to system if low.
Clean fins on radiator if dirty. Tighten
fan belt if loose.

1. Replace
2. Clean and tighten connections.

3. Tighten. See Maintenance Section.
4. Consult authorized Kubota Service

Shop.