CONNECTION DIAGRAMS

F-2

F-2

RANGER 300 D AND 300 DLX

ELECTRODE

TO WORK

14 PIN

TO WORK

AMPHENOL

N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A WIRE WELDING-CV POSITION.

WARNING

Keep guards in place.

or service this equipment.

Keep away from moving parts.
Only qualified personnel should install,use

CONTROL MODULE CONNECTION DIAGRAM

RANGER 300 DLX / LN-25 WITH K624-1 42 VOLT REMOTE OUTPUT

N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

6-20-97

Do not touch electrically live parts.

CABLE PLUG

CAUTION :

THE ENGINE WELDER OPERATING MANUAL.

PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

APPLICATIONS. SEE OPERATING MANUAL.

N.D. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION.

ELECTRODE CABLE

TO WIRE FEED UNIT

TO LN-25 INPUT

K626-XX INPUT CABLE ASSEMBLY

Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.

S23732-3

WARNING

Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.

Do not touch electrically live parts.

ELECTRODE

TO WORK

S23732-4

CAUTION :

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
THE ENGINE WELDER OPERATING MANUAL.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL REMOTE SWITCH IN "REMOTE" POSITION.

APPLICATIONS. SEE OPERATING MANUAL.

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

N.B. USE POLARITY SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A WIRE WELDING-CV POSITION.

N.D. PLACE IDLER SWITCH IN "HIGH" POSITION.

6-20-97

TO LN-7 INPUT
CABLE PLUG

14 PIN
AMPHENOL

OPTIONAL K857
REMOTE CONTROL

6 PIN
AMPHENOL

ELECTRODE CABLE

TO WORK

TO WIRE FEED UNIT

Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.

K584 CONTROL CABLE

RANGER 300 DLX / LN-7 CONNECTION DIAGRAM