Installation, Safety precautions, General description – Lincoln Electric IM626 Mobiflex 200-M Lamp Kit User Manual
Page 9: Warning

If installing a complete K1653-1 or K1653-2
Mobiflex 200-M System
, refer to the Mobiflex
200-M manual for installation information.
If installing a complete Mobiflex 400-MS
System
, refer to the Mobiflex 400-MS manual for
installation information.
This manual covers installation of a
K1669-3 Lamp Kit with Arc Sensor or
K1669-1 Lamp Kit
and optional K1670-1 Arc Sensor
on an existing K1653-1 Mobiflex 200-M system, or
K1706-2 Work Lamp with Arc Sensor or
K1706-1 Work Lamp
and optional K1670-1 Arc Sensor
on an existing Mobiflex 200-M or 400-MS system.
Note: The K1706-1 and K1706-2 Work Lamp options
cannot be combined with a K1653-1 Mobiflex 200-M.
Only qualified personnel should install, use or service
this equipment.
------------------------------------------------------------------------
The K1669-1 Lamp Kit Includes:
Work Lamp
13 ft., 3-Wire, 20 Ga. Connection Cable
Transformer Relay Kit
Screws, (2) 2.9x9.5mm Self-tapping
Screws, (5) 3.5x9.5mm Self-tapping
The K1669-3 Lamp Kit with Arc Sensor Includes:
Work Lamp with Factory-installed
Automatic Start/Stop Arc Sensor
13 ft., 3-Wire, 20 Ga. Connection Cable
Transformer Relay Kit
Screws, (2) 2.9x9.5mm Self-tapping
Screws, (5) 3.5x9.5mm Self-tapping
The K1706-1 Work Lamp Includes:
Work Lamp
13 ft., 3-Wire, 20 Ga. Connection Cable
The K1706-2 Work Lamp with Arc Sensor Includes:
Work Lamp with Factory-installed
Automatic Start/Stop Arc Sensor
13 ft., 3-Wire, 20 Ga. Connection Cable
A-2
INSTALLATION
LAMP OPTIONS FOR MOBIFLEX 200-M
A-2
Read this entire installation section before you
start installation.
SAFETY PRECAUTIONS
Do not attempt to use this equipment until you have
thoroughly read all installation, operating and mainte-
nance information supplied with your equipment. They
include important safety precautions and detailed
operating and maintenance instructions.
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such
as internal wiring.
• Turn the input power off at the fuse box
before working on this equipment.
• Have a qualified person install and ser-
vice this equipment.
------------------------------------------------------------------------
MOVING PARTS can injure.
• Do not operate without extraction arm
installed.
• Keep away from moving parts.
------------------------------------------------------------------------
Only qualified personnel should install, use or service
this equipment.
GENERAL DESCRIPTION
All of the Lamp Options for the Mobiflex 200-M incor-
porate a work lamp with remote, hood-mount switches
for both the Lamp and the Mobiflex 200-M extraction
fan. The 35W lamp fits in the hood of the LFA 3.1 or
LFA 4.1 Arm to provide a convenient, positionable
light at the workspace. The switch for the lamp is
hood-mounted, for accessibility. The convenient dual
switch at the hood also includes a remote switch for
the Mobiflex 200-M extraction system.
The optional K1670-1 Automatic Start/Stop Arc
Sensor can be combined with the K1669-1 Lamp Kit
or K1706-1 Work Lamp to provide automatic switching
on and off of the Mobiflex 200-M when the sensor
detects the arc flash.
The K1669-3 Lamp Kit and the K1706-2 Work Lamp
come with the Arc Sensor already installed in the lamp
housing.
If not installing the Auto Start/Stop Arc Sensor sepa-
rately, skip steps as specified.
WARNING
WARNING