beautypg.com

Installation, Safety precautions, General description – Lincoln Electric IM626 Mobiflex 200-M Lamp Kit User Manual

Page 9: Warning

background image

If installing a complete K1653-1 or K1653-2
Mobiflex 200-M System

, refer to the Mobiflex

200-M manual for installation information.

If installing a complete Mobiflex 400-MS
System

, refer to the Mobiflex 400-MS manual for

installation information.

This manual covers installation of a

K1669-3 Lamp Kit with Arc Sensor or
K1669-1 Lamp Kit

and optional K1670-1 Arc Sensor

on an existing K1653-1 Mobiflex 200-M system, or

K1706-2 Work Lamp with Arc Sensor or
K1706-1 Work Lamp

and optional K1670-1 Arc Sensor

on an existing Mobiflex 200-M or 400-MS system.

Note: The K1706-1 and K1706-2 Work Lamp options
cannot be combined with a K1653-1 Mobiflex 200-M.

Only qualified personnel should install, use or service
this equipment.

------------------------------------------------------------------------

The K1669-1 Lamp Kit Includes:

Work Lamp
13 ft., 3-Wire, 20 Ga. Connection Cable
Transformer Relay Kit

Screws, (2) 2.9x9.5mm Self-tapping
Screws, (5) 3.5x9.5mm Self-tapping

The K1669-3 Lamp Kit with Arc Sensor Includes:

Work Lamp with Factory-installed

Automatic Start/Stop Arc Sensor

13 ft., 3-Wire, 20 Ga. Connection Cable
Transformer Relay Kit

Screws, (2) 2.9x9.5mm Self-tapping
Screws, (5) 3.5x9.5mm Self-tapping

The K1706-1 Work Lamp Includes:

Work Lamp
13 ft., 3-Wire, 20 Ga. Connection Cable

The K1706-2 Work Lamp with Arc Sensor Includes:

Work Lamp with Factory-installed

Automatic Start/Stop Arc Sensor

13 ft., 3-Wire, 20 Ga. Connection Cable

A-2

INSTALLATION

LAMP OPTIONS FOR MOBIFLEX 200-M

A-2

Read this entire installation section before you
start installation.

SAFETY PRECAUTIONS

Do not attempt to use this equipment until you have
thoroughly read all installation, operating and mainte-
nance information supplied with your equipment. They
include important safety precautions and detailed
operating and maintenance instructions.

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts such

as internal wiring.

• Turn the input power off at the fuse box

before working on this equipment.

• Have a qualified person install and ser-

vice this equipment.

------------------------------------------------------------------------

MOVING PARTS can injure.

• Do not operate without extraction arm

installed.

• Keep away from moving parts.

------------------------------------------------------------------------

Only qualified personnel should install, use or service
this equipment.

GENERAL DESCRIPTION

All of the Lamp Options for the Mobiflex 200-M incor-
porate a work lamp with remote, hood-mount switches
for both the Lamp and the Mobiflex 200-M extraction
fan. The 35W lamp fits in the hood of the LFA 3.1 or
LFA 4.1 Arm to provide a convenient, positionable
light at the workspace. The switch for the lamp is
hood-mounted, for accessibility. The convenient dual
switch at the hood also includes a remote switch for
the Mobiflex 200-M extraction system.

The optional K1670-1 Automatic Start/Stop Arc
Sensor can be combined with the K1669-1 Lamp Kit
or K1706-1 Work Lamp to provide automatic switching
on and off of the Mobiflex 200-M when the sensor
detects the arc flash.

The K1669-3 Lamp Kit and the K1706-2 Work Lamp
come with the Arc Sensor already installed in the lamp
housing.

If not installing the Auto Start/Stop Arc Sensor sepa-
rately, skip steps as specified.

WARNING

WARNING