Installation, Fig. 1, Fig. 2 – Lincoln Electric IM626 Mobiflex 200-M Lamp Kit User Manual
Page 10: Fig. 3, Fig. 4, Fig. 5, Lamp options for mobiflex 200-m

MOUNTING THE LAMP HOUSING IN THE HOOD
Feed the lamp (and sensor leads, if used) through the
hole (Fig. 3, Item A) in the top of the hood; push the
top leg of the lamp housing into position, then snap in
the bottom leg. Remount the airflow focus vanes in
the open end of the hood, using the six screws.
MAKING THE CONNECTIONS AT THE HOOD
Feed the 13 ft. connecting cable through the hole in
the hood (Fig. 4, Item B).
Have a qualified electrician connect the 13 ft. connect-
ing cable leads, lamp leads, and sensor leads (if
used) to the control board (Fig. 5, Item B). Push the
board onto the bottom of the remote switch (Fig. 5,
Item C). Snap the switch box into place atop the hood.
GENERAL PREPARATION
1. Pop out the sealing plate (Fig. 1, Item A) on the top
of the hood with a screwdriver.
2. Remove the six screws (Fig. 1, Item C) and the air-
flow focus vanes (Fig. 1, Item B).
3. Open the airflow throttle valve (Fig. 1, Item D).
MOUNTING THE ARC SENSOR IN THE LAMP
HOUSING
If not installing the K1670-1 Auto start/stop arc
sensor, skip to the next step, “Mounting the lamp
housing in the hood”. The K1669-3 Lamp Kit and
K1706-2 Work Lamp have the Arc Sensor built into
the lamp housing.
Note: If the lamp housing assembly has (5) leads, the
Arc Sensor is already installed. Skip to the next step
“Mounting the lamp housing in the hood.”
Use a small phillips-head screwdriver to remove the
six screws that hold the lamp housing (Fig. 2, Item A)
together. Insert the sensor housing (Fig. 2, Item B)
with the sensor ‘eye’ away from the lamp. Route all 5
leads through the lamp housing “leg” and out the
opening as shown in Figure 2. Replace the other half
of the lamp housing, and tighten the screws.
A-3
INSTALLATION
LAMP OPTIONS FOR MOBIFLEX 200-M
A-3
A
B
D
90
°
C
6x
1
2
2
3
Fig. 1
B
A
Fig. 2
A
B
C
Fig. 3
A
B
Fig. 4
WH
BN
GN
IMS
LAMP
WH
BN
GN
BK
BK
A
B
C
To:
Lamp
To:
Arc Sensor
(if used)
13 ft.
Connecting
Cable